Tweco XTTM-300 User Manual

Page 38

Advertising
background image

Operation with Manual Gas Control

4A-14

Manual 0-2912

Aluminum

100A

Ar/H2 Plasma / N2 Shield

Ar

t # A-06839

Manual

Gas Control

!

CAUTION

Manual gas consoles with 3 flow meters cannot be used for 100A cutting with stainless steel.

Cartridge

21-1020

Electrode

21-1080

Plasma

Gas Distributor

21-1041

Tip

21-1062

Shield Cap

21-1036

Shield Cup

21-1016

Art # A-04030

Shield

Gas Distributor

21-1274

(ga)

(in)

H35

N2

N2

N2

N2

N2

-

1/4

35

35

35

35

35

35

161

0.150

100

0.350

0.2

-

3/8

35

35

35

35

35

35

163

0.150

60

0.350

0.2

-

1/2

35

35

35

35

35

35

166

0.150

50

0.350

0.3

-

5/8

60

30

35

35

35

35

173

0.150

40

0.400

0.5

H35

N2

N2

N2

N2

N2

35

35

35

35

35

35

155

3.8

3.3

8.0

0.2

35

35

35

35

35

35

158

3.8

3.0

8.0

0.2

35

35

35

35

35

35

160

3.8

2.8

8.9

0.2

35

35

35

35

35

35

160

3.8

2.5

8.9

0.2

35

35

35

35

35

35

162

3.8

2.0

8.9

0.2

35

35

35

35

35

35

163

3.8

1.5

8.9

0.2

35

35

35

35

35

35

165

3.8

1.3

8.9

0.3

60

30

35

35

35

35

172

3.8

1.1

10.2

0.5

Bold type indicates maximum piercing parameters.

8

10

12

15

3

4

5

6

Torch

Working

Height

(mm)

Travel

Speed

(m/min)

Initial

Piercing

Height

(mm)

Pierce

Delay

(sec)

Travel

Speed

(ipm)

Initial

Piercing

Height

(in)

Pierce

Delay

(sec)

Material

Thickness

(mm)

Cut Flow Rates (%)

Preflow Flow

** Arc

Voltage

(volts)

Plasma %

Shield %

Preflow %

Torch

Working

Height

(in)

Material

Thickness

Cut Flow Rates (%)

Preflow Flow

** Arc

Voltage

(volts)

Plasma %

Shield %

Preflow %

Advertising