Stainless steel 50a air plasma / air shield – Tweco XTTM-300 User Manual
Page 47
Manual 0-2912
4B-9
Operation with 5-Knob Automatic Gas Console
Stainless Steel
50A
Air Plasma / Air Shield
Ar
t # A-06840
1
2
3
4
5
Cartridge
21-1020
Electrode
21-1078
Plasma
Gas Distributor
21-1041
Tip
21-1060
Shield Cap
21-1034
Shield Cup
21-1016
Art # A-04029
Shield
Gas Distributor
21-1274
Plasma
(ga)
(in)
Air
(1*)
(2*)
Air
(3*)
Air
(4*)
(5*)
(Dial)
(sec)
14
0.075
80
-
65
65
-
113
0.060
120
0.120
0.0
0.0
12
0.105
80
-
65
65
-
117
0.060
80
0.150
0.0
0.0
10
0.135
80
-
65
65
-
121
0.060
55
0.180
0.0
0.1
-
0.188
80
-
65
65
-
123
0.080
40
0.250
1.0
0.3
Plasma
Air
(1*)
(2*)
Air
(3*)
Air
(4*)
(5*)
(Dial)
(sec)
80
-
65
65
-
109
1.5
4.0
2.3
0.0
0
80
-
65
65
-
111
1.5
3.6
2.6
0.0
0
80
-
65
65
-
113
1.5
2.9
3.1
0.0
0
80
-
65
65
-
119
1.5
1.8
4.1
0.0
0.1
80
-
65
65
-
122
1.5
1.2
5.3
0.5
0.2
80
-
65
65
-
123
2.0
0.9
6.7
1.0
0.3
Bold type indicates maximum piercing parameters.
* Refers to Control Knob Number
Material
Thickness
Cut Flow Rates
Preflow Flow
** Arc
Voltage
(volts)
Shield
Preflow
Torch
Working
Height
(in)
Travel
Speed
(ipm)
Initial
Piercing
Height
(in)
Pierce Delay
Initial
Piercing
Height
(mm)
Pierce Delay
Preflow Flow
** Arc
Voltage
(volts)
Shield
Preflow
Torch
Working
Height
(mm)
Travel
Speed
(m/min)
1.2
5.0
1.5
2.0
3.0
4.0
Material
Thickness
(mm)
Cut Flow Rates