Aluminum 50a air plasma / air shield – Tweco XTTM-300 User Manual

Page 62

Advertising
background image

Operation with 6-Knob Automatic Gas Console

4C-12

Manual 0-2912

Aluminum

50A

Air Plasma / Air Shield

Ar

t # A-06841

1

2

3

4

6

5

Cartridge

21-1020

Electrode

21-1078

Plasma

Gas Distributor

21-1041

Tip

21-1060

Shield Cap

21-1034

Shield Cup

21-1016

Art # A-04029

Shield

Gas Distributor

21-1274

(ga)

(in)

(1)*

Air

(2)*

Air

(3)*

(4)*

Air

(5)*

(6)*

(Dial)

(sec)

14

0.075

-

65

80

-

65

-

135

0.100

135

0.150

0.0

0.0

12

0.105

-

65

80

-

65

-

139

0.105

90

0.200

0.0

0.0

10

0.135

-

65

80

-

65

-

142

0.110

60

0.200

0.0

0.0

-

3/16

-

65

80

-

65

-

145

0.120

40

0.250

0.5

0.2

(1)*

Air

(2)*

Air

(3)*

(4)*

Air

(5)*

(6)*

(Dial)

(sec)

-

65

80

-

65

-

130

2.5

4.6

3.5

0.0

0.0

-

65

80

-

65

-

130

2.5

4.5

3.5

0.0

0.0

-

65

80

-

65

-

130

2.5

4.3

3.5

0.0

0.0

-

65

80

-

65

-

133

2.8

4.0

3.7

0.0

0.0

-

65

80

-

65

-

133

2.8

3.8

3.7

0.0

0.0

-

65

80

-

65

-

135

2.8

3.2

4.0

0.0

0.0

-

65

80

-

65

-

142

2.8

1.5

5.1

0.0

0.0

-

65

80

-

65

-

123

3.0

1.2

6.5

0.5

0.2

-

65

80

-

65

-

145

3.0

1.0

6.5

0.5

0.2

* Refers to Control Knob Number

Bold type indicates maximum piercing parameters.

Material

Thickness

Preflow Flow

Cut Flow Rates

** Arc

Voltage

(volts)

Preflow

Shield

Plasma

Torch

Working

Height

(in)

Travel

Speed

(ipm)

Initial

Piercing

Height

(in)

Pierce Delay

Pierce Delay

Material

Thickness

(mm)

Preflow Flow

Cut Flow Rates

** Arc

Voltage

(volts)

Preflow

Shield

Plasma

1.2

Torch

Working

Height

(mm)

Travel

Speed

(m/min)

Initial

Piercing

Height

(mm)

0.6

0.8

1

5

1.5

2

3

4

Advertising