Cutmaster 40mm – Tweco 40mm Cutmaster User Manual
Page 17
CUTMASTER 40mm
Manual 0-5084
2-3 INTRODUCTION
2.05 Input Wiring Specifications
CutMaster 40 Power Supply Input Cable Wiring Requirements
Input voltage Freq Power Input
Suggested Sizes
Volts
Hz
kVA
I max I eff
Fuse
(amps)
Flexible Cord
(Min. AWG)
Flexible Cord
(Min. mm
2
)
3 Phase
380
50
23
35
32
40
8
10
400
50
23.6
34
31
40
8
10
Line Voltages with Suggested Circuit Protection and Wire Sizes
Based on National Electric Code and Canadian Electric Code
NOTE
Refer to Local and National Codes or local authority having jurisdiction for proper wiring requirements.
The suggested sizes are based on flexible power cable with power plug installations. For hard-wired installations
refer to local or national codes.
I1max is taken at TDC rated minimum duty cycle.
I1eff is taken at TDC 100% rated duty cycle.