Cutmaster 40mm – Tweco 40mm Cutmaster User Manual

Page 61

Advertising
background image

CUTMASTER 40mm

Manual 0-5084

5-7

SERVICE

5. Remove the fitting from the filter element

assembly by inserting a 6 mm hex wrench

into the internal hex fitting and turning it

counter clock-wise (left). Numbers 4 and 5

in the previous illustration.

6. Disconnect the input line from the filter

element assembly.

7. Remove the filter element assembly

through the rear opening.

NOTE

If replacing or cleaning just the filter element

refer to the following illustration for disassembly.

Art # A-07990

Filter Element

8. Install the new or cleaned assembly by

reversing these procedures.

9. Turn ON the air supply and check for leaks

before reinstalling the cover.

Optional Single-Stage Filter Element

Replacement

These instructions apply to power supplies where

the optional Single-Stage Filter has been installed.

The Power Supply shuts down automatically

when the Filter Element becomes completely sat-

urated. The Filter Element can be removed from

its housing, dried, and reused. Allow 24 hours for

Element to dry. Refer to Section 6, Parts List, for

replacement filter element catalog number.

1. Remove power from power supply.

2. Shut OFF air supply and bleed down sys-

tem before disassembling Filter to change

Filter Element.

3. Disconnect gas supply hose.

4. Turn the Filter Housing Cover counter-

clockwise and remove it. The Filter Ele-

ment is located inside the Housing.

Art # A-02476

Filter

Element

(Cat. No. 9-7741)

Housing

Cover

Barbed

Fitting

Spring

Assembled Filter

O-ring

(Cat. No. 9-7743)

Optional Single-Stage Filter Element Replacement

5. Remove the Filter Element from the Hous-

ing and set Element aside to dry.

6. Wipe inside of housing clean, then insert

the replacement Filter Element open side

first.

7. Replace Housing on Cover.

8. Reattach gas supply.

NOTE

If unit leaks between housing and cover, inspect

the O-Ring for cuts or other damage.

Advertising