CUTMASTER 40mm

Manual 0-5084

4T-19 OPERATION

Type Torch: SL100 With Shielded Tip

Type Material: Mild Steel

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm

(Cat. No.) Volts(VDC)

(Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.250 6.4

9-8253

140

120

165

4.19

0.125 3.2

75

5.2

180

360

0.20

0.20

5.1

0.375 9.5

9-8253

142

120

85

2.16

0.125 3.2

75

5.2

180

360

0.50

0.20

5.1

0.500 12.7

9-8253

144

120

75

1.91

0.125 3.2

75

5.2

180

360

0.70

0.20

5.1

0.625 15.9

9-8253

150

120

50

1.27

0.125 3.2

75

5.2

180

360

0.80

0.20

5.1

0.750 19.0

9-8253

154

120

30

0.76

0.150 3.8

75

5.2

180

360

1.50

0.20

5.1

0.875 22.2

9-8253

158

120

25

0.64

0.150 3.8

75

5.2

180

360

NR

NR

NR

1.000 25.4

9-8253

160

120

20

0.51

0.150 3.8

75

5.2

180

360

NR

NR

NR

1.250 31.8

9-8253

170

120

13

0.33

0.175 4.4

75

5.2

180

360

NR

NR

NR

1.500 38.1

9-8253

176

120

8

0.20

0.175 4.4

75

5.2

180

360

NR

NR

NR

Type Torch: SL100 With Shielded Tip

Type Material: Stainless Steel

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm (Cat. No.) Volts(VDC)

(Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.250 6.4 9-8253

136

120

180

4.57

0.13

3.2

75

5.2

180

360

0.20

0.20

5.1

0.375 9.5 9-8253

144

120

100

2.54

0.13

3.2

75

5.2

180

360

0.40

0.20

5.1

0.500 12.7 9-8253

149

120

60

1.52

0.13

3.2

75

5.2

180

360

0.80

0.20

5.1

0.625 15.9 9-8253

153

120

40

1.02

0.15

3.8

75

5.2

180

360

1.20

0.20

5.1

0.750 19.1 9-8253

157

120

30

0.76

0.15

3.8

75

5.2

180

360

NR

NR

NR

1.000 25.4 9-8253

162

120

20

0.51

0.15

3.8

75

5.2

180

360

NR

NR

NR

1.250 31.8 9-8253

165

120

10

0.25

0.15

3.8

75

5.2

180

360

NR

NR

NR

Type Torch: SL100 With Shielded Tip

Type Material: Aluminum

Type Plasma Gas: Air

Type Secondary Gas: Single Gas Torch

Thickness

Tip

Output

Amperage Speed (Per Minute)

Standoff

Plasma Gas Press

Flow (CFH)

Pierce

Pierce Height

Inches mm (Cat. No.) Volts(VDC)

(Amps)

Inches

Meters

Inches mm

psi*

bar

Plasma Total** Delay (Sec) Inches mm

0.250 6.4 9-8253

144

120

190

4.83

0.13

3.2

75

5.2

180

360

0.20

0.20

5.1

0.375 9.5 9-8253

148

120

120

3.05

0.13

3.2

75

5.2

180

360

0.50

0.20

5.1

0.500 12.7 9-8253

152

120

75

1.91

0.15

3.8

75

5.2

180

360

0.70

0.20

5.1

0.625 15.9 9-8253

162

120

45

1.14

0.15

3.8

75

5.2

180

360

1.00

0.20

5.1

0.750 19.1 9-8253

163

120

35

0.89

0.15

3.8

75

5.2

180

360

NR

NR

NR

1.000 25.4 9-8253

168

120

20

0.51

0.15

3.8

75

5.2

180

360

NR