CUTMASTER 40mm

INSTALLATION 3-4

Manual 0-5084

Using High Pressure Air Cylinders

When using high pressure air cylinders as the air

supply:

1. Refer to the manufacturer’s specifications

for installation and maintenance proce-

dures for high pressure regulators.

2. Examine the cylinder valves to be sure

they are clean and free of oil, grease or any

foreign material. Briefly open each cylin-

der valve to blow out any dust which may

be present.

3. The cylinder must be equipped with an

adjustable high - pressure regulator capable

of outlet pressures up to 100 psi (6.9 bar)

maximum and flows of at least 300 scfh

(141.5 lpm).

4. Connect supply hose to the cylinder.

NOTE

Pressure should be set at 100 psi (6.9 bar) at the

high pressure cylinder regulator.
Supply hose must be at least 1/4 inch (6 mm)

I.D.
For a secure seal, apply thread sealant to the

fitting threads, according to manufacturer's

instructions. Do Not use Teflon tape as a thread

sealer, as small particles of the tape may break

off and block the small air passages in the torch.