CUTMASTER 40mm

SERVICE

5-8

Manual 0-5084

Optional Two-Stage Filter Element

Replacement

The Two-Stage Air Filter has two Filter Elements.

When the Filter Elements become dirty the Power

Supply will continue to operate but cut quality

may become unacceptable. Refer to Section 6,

Parts List, for replacement filter element catalog

number.

1. Shut OFF primary input power.

2. Shut OFF air supply and bleed down sys-

tem.

WARNING

Always turn OFF the air supply and bleed the system

before disassembling the Filter Assembly as injury

could result.

3. Loosen the two bolts on the top of the

Filter Assembly enough to allow the Filter

Elements to move freely.

4. Note the location and orientation of the old

Filter Elements.

5. Slide out the old Filter Elements.

First & Second

Stage

Cartridges

(as marked)

Art # A-02942

Optional Two-Stage Filter Replacement

6. Slide the replacement Filter Elements into

the Filter Assembly, with the same orienta-

tion as noted in Step 4 above.

7. Hand tighten the two bolts evenly, then

torque each bolt to 20 - 30 in-lbs (2.3 - 3.4

Nm). Improper torque may damage the

gasket.

8. Slowly apply air pressure to the assembly,

checking for leaks.

NOTE

A small amount of air leakage from the bottom

fitting is normal.

This completes the parts replacement procedures.