Ultra-cut 300 xt – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual

Page 156

Advertising
background image

ULTRA-CUT 300 XT

�50

PPENDIX

Manual 0�5�7�

Reasons why RAS Control relay would not close:

6. Pilot current flowing. There actually is pilot current flowing somewhere. Unlikely as it would normally set

the �08 fault but we have to rule it out.

a. Disconnect J�1 on the Pilot board, if HF still doesn’t fire and the Relay board Pilot LED, D11, is still

on, it’s due to a fault in the detection circuits.

7. Faulty detection circuit. There isn’t any pilot current but a fault in the circuits measuring pilot current is

indicating there is current.

a. Measure between pins 8 (�) and 9 (+) on the Pilot ribbon cable from Relay board J3 to Pilot board J��. If

there is no pilot current it should be zero. nything else indicates the Pilot board current sensor is faulty

causing the Relay board D11 to be on. Replace the Pilot board assembly.

b. If the Pilot current signal on the pilot ribbon cable was zero, measure between pins �3 (�) and �5 (+) on

the �0 pin ribbon cable between the Relay board and the CCM. This would also normally be zero if there

is no pilot current. nything else would indicate the Relay board is faulty.

Art # 12307

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

J23

TO RELAY BOARD

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

38

39

40

J4

From I/O PCB

24VDC_SW

D21

GREEN

D23

RF ON

1

5

3

4

K2

RAS CONTROL

120

VA

C

120 VAC to RAS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

J8

120

VA

C

R

ET

120 VAC_1

From J9-1

120 VAC_RET

From J9-7

CCM I/O Board

Relay & Interface Board

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J59 - RAS

(98)

(99)

T2

120 / 6000 VAC

(98)

(99)

6.5K 1W

6.5K 1W

AC200XT only

(Rear Panel)

TP1

GND

TP1

GND

/ RAS ON

8. If “ /RS ON” signal is low on pin 16 of the �0 pin ribbon cable, relative to TP1 on the CCM I/O board,

during the ignition time then we need to determine if the Relay board is defective. If /RS ON signal is

not low the CCM or the �0 pin ribbon cable may be defective.

a. If the Relay board RF ON LED, D�3, is not on while the /RS ON signal is low, then the Relay board is

defective.

b. Is D�3 is on, measure for 1�0 VC on J8�3 to J8�11. If not present the Relay board is defective.

c. If 1�0 VC is present at J8 during the ignition time go back and perform steps ���.

Advertising