Ultra-cut 300 xt, 01 installation requirements – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual

Page 25

Advertising
background image

ULTRA-CUT 300 XT

Manual 0-5274

INSTALLATION

3-1

SECTION 3: INSTALLATION

3.01 Installation Requirements

Electric Supply

The electrical supply network, the gas and water supply system must meet local safety standards. This confor-

mity shall be checked by qualified personnel.

Ultra-Cut 300 XT™ Power Supply

Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps) Wire (AWG) Wire (mm

2

)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

480

50/60

63

77

150

#4

25

IEC

480

50/60

72

88

150

#4

25

NOTE

* Suggested wire size based on United States NFPA 70 National Electrical Code 2011 edition pub-

lished by the National Fire Prevention Association. Listings are from table 400.5(A)(2) for flexible cord

of certain types rated for 75 deg C in ambient temperatures up to 30 deg C. Using wires of lower

temperature rating or different insulation type may require larger wire size. Derate for higher ambient.

These are suggestions only. Always refer to your local and national codes that apply to your region for

final determination of correct wire type and size.

Gas Supply

The customer must supply all gases and pressure regulators. Gases must be of high quality. Pressure regulators

must be double-stage and installed as close as possible to the gas console. Contaminated gas can cause one or

more of the following problems:

• Reduced cutting speed
• Poor cut quality
• Poor cutting precision
• Reduced consumables life.
• Oil or grease contamination from compressed or bottled air can cause fires in conjunction with oxygen.

Cooling System Requirements

Coolant must be added to the system on installation. The amount required varies with torch leads length.

Victor Thermal Dynamics recommends the use of its coolants 7-3580 and 7-3581 (for low temperatures).

Coolant Capabilities

Cat. Number and Mixture

Mixture

Protects To

7-3580 ‘Extra-Cool™’

25 / 75

10° F / -12° C

7-3581 ‘Ultra-Cool™’

50 / 50

-27° F / -33° C

7-3582 ‘Extreme Cool™’

Concentrate*

-76° F / -60° C

* For mixing with D-I Cool™ 7-3583