Ultra-cut 300 xt – Tweco 300 XT Ultra-Cut Plasma Cutting System User Manual

Page 52

Advertising
background image

ULTRA-CUT 300 XT

3-28

INSTALLATION

Manual 0-5274

Output Connections

1. Refer to the illustrations. Make the following output connections to the Arc Starter.

Pilot Lead

Art # A-12065

Green

Red

Coolant Return (Red)

Coolant Supply (Green)

Pilot Return Cable, Coolant Supply and Return Hoses (from Torch)

2. Reinstall the Arc Starter Cover. Ensure that the ground wire is not crimped between the cover and the base.

Art # A-12059

Lower screws

(2 per side)

Upper screws (2 per side)

Cover

Ground Wire