Installation thermal arc 161 s, 05 setup for welding – Tweco 161 S Inverter Arc Welder User Manual

Page 21

Advertising
background image

INSTALLATION

THERMAL ARC 161 S

Manual 0-5199

3-5 Installation

5. Earthing of the Work Piece
Where the work piece is not bonded to earth for

electrical safety, nor connected to earth because of its

size and position, e.g. ship’s hull or building steelwork,

a connection bonding the work piece to earth may

reduce emissions in some, but not all instances. Care

should be taken to prevent the earthing of the work

piece increasing the risk of injury to users, or damage

to other electrical equipment. Where necessary, the

connection of the work piece to earth should be made

by direct connection to the work piece, but in some

countries where direct connection is not permitted, the

bonding should be achieved by suitable capacitance,

selected according to national regulations.

6. Screening and Shielding
Selective screening and shielding of other cables

and equipment in the surrounding area may alleviate

problems of interference. Screening the entire

welding installation may be considered for special

applications.

3.05 Setup for Welding

NOTE

Conventional operating procedures apply

when using the Welding Power Source, i.e.

connect work lead directly to work piece and

electrode lead is used to hold electrode. Wide

safety margins provided by the design ensure

that the Welding Power Source will withstand

short-term overload without adverse effects.

The welding current range values should be

used as a guide only. Current delivered to the

arc is dependent on the welding arc voltage,

and as welding arc voltage varies between

different classes of electrodes, welding current

at any one setting would vary according to the

type of electrode in use. The operator should

use the welding current range values as a

guide then fine tune the welding current to

suit the application.

WARNING

Before connecting the work clamp to the work

and inserting the electrode in the electrode

holder make sure the Primary power supply

is switched off.

CAUTION

Remove any packaging material prior to use.

Do not block the air vents at the front or rear

of the Welding Power Source.