Thermal arc 161 s operation, 02 welding current control explanation – Tweco 161 S Inverter Arc Welder User Manual

Page 28

Advertising
background image

THERMAL ARC 161 S

OPERATION

Operation

4-2

Manual 0-5199

4.02 Welding Current Control

Explanation

15 Amp Outlet

The mains power 15 Amp circuit breaker or fuse should

not trip at this Weld Current value when STICK welding.
The environmental conditions that may cause the mains

power 15 Amp circuit breaker or fuse to trip are:

a) High ambient temperature

b) Worn parts in circuit breaker

c) Using an extension cable

d) Low line mains power voltage

20 Amp Outlet

The mains power 20 Amp circuit breaker or fuse should

not trip at this Weld Current value when STICK welding.
The environmental conditions that may cause the mains

power 20 Amp circuit breaker or fuse to trip are:

a) High ambient temperature

b) Worn parts in circuit breaker

c) Using an extension cable

d) Low line mains power voltage

Output Scale for 115V

The inside number scale identifies the available

output weld current for STICK or LIFT TIG weld modes.

STICK Mode:

Identifies the STICK weld point for 15

Amp outlet.

Identifies the STICK weld point for 20

Amp outlet.

Exceeding these points will cause nui-

sance tripping of the circuit breaker or

fuse.

LIFT TIG Mode: A 15 Amp outlet is capable of supply-

ing enough input power for all LIFT TIG

output weld current values.

Nuisance tripping should not occur on a 15 Amp outlet.
Output Scale for 208/230V

The outside number scale identifies the available output

weld current for STICK or LIFT TIG weld modes.
Nuisance tripping should not occur on a 50A 208/230V

outlet for both STICK & LIFT TIG Modes.

PROCESSUS

PROCESS

SMAW

GTAW

SMAW

GTAW

15A

SMAW

20A

115V

50A

SMAW

GTAW

208/

230V

15 Amp Outlet

20 Amp Outlet

Output Scale for 115V

Output Scale for 230V

Art# A-10382

Figure 4-2: Current Control

Advertising