Operation thermal arc 161 s, 01 front panel – Tweco 161 S Inverter Arc Welder User Manual

Page 27

Advertising
background image

OPERATION

THERMAL ARC 161 S

Manual 0-5199

4-1

Operation

Figure 4-1: Thermal Arc 161 S Controls

SECTION 4:

OPERATION

Conventional operating procedures apply when using the

Welding Power Source, i.e. connect work lead directly to

work piece and electrode lead is used to hold the electrode.

The welding current range values should be used as a

guide only. Current delivered to the arc is dependent on

the welding arc voltage, and as welding arc voltage varies

between different classes of electrode, welding current at

any one setting would vary according to the type of elec-

trode in use. The operator should use the welding current

range values as a guide then fine tune the welding current

to suit the specific application. Refer to the electrode

manufacture's literature for further information.

4.01 Front Panel

Front Panel

The welding power source is protected by a self re-setting

thermostat. The indicator will illuminate if the duty cycle

of the power source has been exceeded. If the Over Heat

light illuminates wait for the Over Heat light to extinguish

before resuming welding.
(A) Process Selection Switch
Switches between LIFT TIG and STICK Welding modes.
(B) Power On Indicator
The Power ON Indicator illuminates when the ON/OFF

switch is in the ON position and the nominal mains volt-

age is present.

(C) Fault Indicator
The welding power source is protected by a self resetting

thermostat and over primary current protection devices.

Welding can not take place if the Fault Indicator lights up

or lights up continuously.
Thermostat Protection
If the Fault Indicator lights up then the duty cycle of the

power source has been exceeded, Leave the power on

and wait for the Warning Indicator to extinguish before

resuming welding.
Over Primary Current Protection
If the Fault Indicator lights up continuously then the

primary current into the main transformer has been ex-

ceeded. Have an Accredited Thermal Arc Service Provider

inspect then repair the welder.
(D) Welding Current Control
The welding current is increased by turning the Weld

Current control knob clockwise or decreased by turning

the Weld Current control knob counterclockwise. The

welding current should be set according to the specific

application. Refer to the electrode manufacture's literature

for further information.
(E) ON/OFF Switch (located on rear panel - not
shown)
This switch controls the Mains Supply Voltage to the

Power Source.

PROCESSUS

PROCESS

SMAW

GTAW

SMAW

GTAW

15A

SMAW

20A

115V

50A

SMAW

GTAW

208/

230V

(B) Power On Indicator

(C) Fault Indicator

(A) Process

Selection

Switch

(D) Welding

Current

Control

Art# A-10381

Advertising