Thermal arc 161 s installation, 08 victor regulator – Tweco 161 S Inverter Arc Welder User Manual

Page 24

Advertising
background image

THERMAL ARC 161 S

INSTALLATION

Installation 3-8

Manual 0-5199

9. Set the “Process Selection Switch” to LIFT TIG
10. Set the weld current control knob to the desired

amperage.

11. The tungsten must be ground to a blunt point in order

to achieve optimum welding results. It is critical

to grind the tungsten electrode in the direction the

grinding wheel is turning.

12. Install the tungsten with approximately 1/8” to ¼”

sticking out from the gas cup, ensuring you have

correct sized collet.

13. Tighten the back cap then open the valve on the

torch.

14. You are now ready to begin TIG Welding.

3.08 Victor Regulator

Pressure regulator (Figure 3-4) attached to the cylinder

valve reduce high cylinder pressures to suitable low

working pressures for welding, cutting, and other

applications.

LOW PRESSURE

GAUGE (DELIVERY)

HIGH PRESSURE

GAUGE (SUPPLY)

INLET

CONNECTION

OUTLET

CONNECTION

PRESSURE

ADJUSTING

SCREW

Art # A-09414

Figure 3-4: Victor CS Regulator

!

WARNING

Use the regulator for the gas and pressure for

which it is designed. NEVER alter a regulator

for use with any other gas.

NOTE

Regulators purchased with open 1/8”, 1/4”,

3/8”, or 1/2” NPT ports must be assembled

to their intended system.

1. Note the maximum inlet pressure stamped on the

regulator. DO NOT attach the regulator to a system

that has a higher pressure than the maximum

rated pressure stamped on the regulator.

2. The regulator body will be stamped “IN” or “HP”

at the inlet port. Attach the inlet port to the system

supply pressure connection.

3. Wrap pipe threads with Teflon tape 1 1/2 to 2

turns to effect a seal. If other sealants are used,

they must be compatible with the gas that will be

used in the system.

4. If gauges are to be attached to the regulator and

the regu lator is stamped and listed by a third party

(i.e. “UL” or “ETL”). The following requirements

must be met:
a) Inlet gauges over 1000 PSIG (6.87 mPa) shall

conform with the requirements of UL 404,

“Indicating Pressure Gauges for Compressed

Gas Service.”

b) Low pressure gauges must be UL recognized

for the class of regulator they are being used

on according to UL252A.

!

WARNING

DO NOT use a regulator that delivers

pressure exceeding the pressure rating of the

downstream equipment unless pro visions

are made to prevent over-pressurization (i.e.

system relief valve). Make sure the pressure

rating of the down stream equipment is

compatible with the maximum delivery

pressure of the regulator.

5. Be sure that the regulator has the correct pressure

rating and gas service for the cylinder used.

6. Carefully inspect the regulator for damaged

threads, dirt, dust, grease, oil, or other flammable

substances. Remove dust and dirt with a clean

cloth. Be sure the inlet swivel filter is clean and

in place. Attach the regulator (Figure 3-5) to the

cylinder valve. Tighten securely with a wrench.