INSTALLATION

THERMAL ARC 161 S

Manual 0-5199

3-9 Installation

!

WARNING

DO NOT attach or use the regulator if oil,

grease, flamma ble substances or damage is

present! Have a qualified repair technician

clean the regulator or repair any damage.

Art # A-09845

Figure 3-5: Regulator to Cylinder Valve

7. Before opening the cylinder valve, turn the

regulator adjusting screw counterclockwise until

there is no pressure on the adjusting spring and

the screw turns freely.

8. Relief Valve (where provided): The relief valve is

designed to protect the low pressure side of the

regulator from high pres sures. Relief valves are

not intended to protect down stream equipment

from high pressures.

!

WARNING

DO NOT tamper with the relief valve or remove

it from the regulator.

!

WARNING

Stand to the side of the cylinder opposite the

regulator when opening the cylinder valve.

Keep the cylinder valve between you and the

regulator. For your safety, NEVER STAND IN

FRONT OF OR BEHIND A REGULATOR WHEN

OPENING THE CYLINDER VALVE!

9. Slowly and carefully open the cylinder valve

(Figure 3-6) until the maximum pressure shows

on the high pressure gauge.

Art # A-09828

Figure 3-6: Open Cylinder Valve

10. On all cylinders, except acetylene, open the valve

completely to seal the valve packing. On gaugeless

regulators, the indicator will register the cylinder

contents open.

11. On acetylene cylinders, open the valve 3/4 of a

turn and no more than 1-1/2.

!

WARNING

Acetylene delivery pressure must not exceed

15 PSIG (103 kPa) or 30 PSIG (207 kPa).

Acetylene can dissociate (decompose with

explosive violence) above these pressure

limits.

CAUTION

Keep the cylinder valve wrench, if one is

required, on the cylinder valve to turn off the

cylinder quickly, if necessary.

12. Attach the desired downstream equipment.