19


3.04 Specifications

Parameter
Rated Output
Amperes
Volts
Duty Cycle

300 TS

400VAC
300
32
40%

Duty Cycle

300A / 32V @ 40% (3ph)
250A / 30V @ 60% (3ph)
180A / 28V @ 100% (3ph)

Output Current Range

5 – 300 Amps

Open Circuit Voltage

65V

Dimensions
Width
Height
Length


8.3” (210mm)
16.5” (420mm)
17.7” (450mm)

Weight

52.9 lb. 24 kg

Output @ Rated Load
Output Amperes
Output Volts
Duty Cycle
KVA
KW

Three-phase

300A
32V
40%
16.0
12.0

Output @ No Load
KVA
KW


0.5
0.13

Input Volts Three Phase

400V

Amperage Draw @ Rated Load

24

No Load

0.7