4.04 Weld Parameters for ArcMaster 300 TS

Weld

Mode

Weld

Parameter

Parameter Range

Factory

Setting

Incremental

Unit

STICK

HF

TIG

LIFT

TIG

PRE-FLOW

0.0 to 1.0 sec

0 sec

0.1 sec

No

Yes

Yes

HOT START

0 to 70A

20A

1A

Yes

Yes

No

INITIAL CUR.

5 to 300A

30A

1A

No

Yes

Yes

UP SLOPE

0 to 15 sec

1 sec

0.1 sec

No

Yes

Yes

PEAK CUR.

5 to 300A

120A

1A

No

Yes

Yes

WELD CUR

(TIG)

5 to 300A

80A

1A

No

Yes

Yes

WELD CUR (STICK)

5 to 300A

80A

1A

Yes

No

No

SPOT TIME

0.5 to 5.0 sec

2 sec

0.1 sec

No

Yes

Yes

PULSE WIDTH

15 to 80%

50%

1%

No

Yes

Yes

PULSE FREQ.

0.5 to 500Hz

100.0Hz

See

Table 6

No Yes

Yes

DOWN SLOPE

0 to 25 sec

3 sec

0.1 sec

No

Yes

Yes

CRATER CUR.

5 to 40A

30A

1A

No

Yes

Yes

POST-FLOW

0.0 to 60 sec

10 sec

0.1 sec

No

Yes

Yes

Table 5 – Weld Parameters for ArcMaster 300 TS