SECTION 7: BASIC TIG WELDING GUIDE


7.01 Electrode Polarity

Connect the TIG torch to the - / TORCH terminal and the work lead to the + / WORK terminal for
direct current straight polarity. Direct current straight polarity is the most widely used polarity
for DC TIG welding. It allows limited wear of the electrode since 70% of the heat is
concentrated at the work piece.

7.02 Tungsten Electrode Current Ranges

Electrode Diameter

DC Current (Amps)

0.040” (1.0mm)

30 – 60

1/16” (1.6mm)

60 – 115

3/32” (2.4mm)

100 – 165

1/8” (3.2mm)

135 – 200

5/32” (4.0mm)

190 – 280

3/16” (4.8mm)

250 – 340

Table 7 – Current Ranges for Various Tungsten Electrode Sizes

7.03 Tungsten Electrode Types

Electrode Type

(Ground Finish)

Welding Application

Features

Color

Code

Thoriated 2%

DC welding of mild steel,
stainless steel and copper.

Excellent arc starting, long life,
high current carrying capacity.

Red

Zirconated 1%

High quality AC welding of
aluminium, magnesium and
their alloys.

Self cleaning, long life,
maintains balled end, high
current carrying capacity.

White

Ceriated 2%

AC & DC welding of mild steel,
stainless steel, copper,
aluminium, magnesium and
their alloys.

Longer life, more stable arc,
Easier starting, wider current
range, narrower more
concentrated arc.

Grey

Table 8 – Tungsten Electrode Types