31

6.01 Stick Welding
• Connect work lead to negative terminal
• Connect electrode lead to positive terminal
• Switch machine ON
• Set Contactor
• Connect remote control device if required

Use the Scroll Buttons to move to the parameter to be set. The LED will show which function is being
adjusted on the weld sequence graph. Use the control knob to adjust each parameter.
• Set

HOT START

• Set

WELD

current

Commence welding

6.02 HF TIG & Lift TIG Welding

• Connect work lead to positive terminal
• Connect TIG torch to negative terminal
• Switch machine ON
• Set weld current
• Connect remote control device. A remote control device is required for use during

LIFT TIG and HF TIG operation. See section 4.01, section 2 “

Remote Control Socket

”,

for complete details of the remote device.


Use the Scroll Buttons to move to the parameter to be set. The LED will show which function
is being adjusted on the weld sequence graph. Use the control knob to adjust each parameter.

• Set

PRE-FLOW

time

• Set

HOT START

current

• Set

POST-FLOW

time

• Set

WELD

current

• Set

POST-FLOW

time

Slope Mode Parameters if required

• Set

INTIAL CUR

current

• Set

UP SLOPE

time

• Set (WELD)

PEAK CUR

current

• Set

BASE

current

• Set

DOWN SLOPE

time

• Set

CRATER CUR

current

Pulse Mode Parameters if required

• Set

PULSE WIDTH

% for

PEAK CURRENT

• Set

PEAK CURRENT

• Set

PULSE FREQ


Commence welding