24

4.03 Weld Parameter Description

Figure 5. ArcMaster 300 TS Front Panel with Parameter Description

Parameter Description

PRE-FLOW

This parameter operates in TIG modes only and is used to get gas to the weld zone
prior to striking the arc, once the torch trigger switch has been pressed. This
control is used to dramatically reduce weld porosity at the start of a weld.

HOT START

This parameter operates in all weld modes except Lift TIG mode and is used to
heat up the weld zone in TIG modes or improve the start characteristics for stick
electrodes. e.g. low hydrogen electrodes. It sets the peak start current on top of
the

PEAK (WELD)

current.

e.g.

HOT START

current = 130 amps when

PEAK (WELD)

= 100 amps

&

HOT START

= 30 amps

INITIAL CUR.

This parameter operates in

SLOPE

or

REPEAT

(4T) TIG modes only and is used to

set the start current for TIG. The Start Current remains ON until the torch trigger
switch is released after it has been depressed.

UP SLOPE

This parameter operates in TIG modes only and is used to set the time for the weld
current to ramp up, after the torch trigger switch has been pressed then released,
from INITIAL CUR to PEAK or BASE current.

PEAK CUR.

This parameter sets the PEAK weld current when in

PULSE

mode.

Advertising