Section 3: installation, 01 environment, 02 location – Tweco 251 Thermal Arc Fabricator User Manual

Page 23: 03 ventilation, Section 3, Installation -1, Fabricator 251

Advertising
background image

FABRICATOR 251

Manual No. 0-4847

3-1

INSTALLATION

SECTION 3:

INSTALLATION

3.01 Environment

The Fabricator 251 is NOT designed for use in
environments with increased hazard of electric shock.

Examples of environments with increased hazard of
electric shock are:

In locations in which freedom of movement is restricted,
so that the operator is forced to perform the work in a
cramped (kneeling, sitting or lying) position with physical
contact with conductive parts;

In locations which are fully or partially limited by
conductive elements, and in which there is a high risk of
unavoidable or accidental contact by the operator, or

In wet or damp hot locations where humidity or
perspiration considerably reduces the skin resistance of
the human body and the insulation properties of
accessories.

Environments with increased hazard of electric shock do
not include places where electrically conductive parts in
the near vicinity of the operator, which can cause increased
hazard, have been insulated.

3.02 Location

Be sure to locate the Power Supply according to the
following guidelines:

In areas, free from moisture and dust.

In areas, free from oil, steam and corrosive gases.

In areas, not subjected to abnormal vibration or shock.

In areas, not exposed to direct sunlight or rain.

Place at a distance of 1 ft (300 mm) or more from walls
or similar that could restrict natural air flow for cooling.

The minimum ground clearance for these products is 5.5"
(140mm).

3.03 Ventilation

Since the inhalation of welding fumes can be harmful,
ensure that the welding area is effectively ventilated.

Advertising