16 polarity changeover, 16 polarity changeover -14, Fabricator 251 – Tweco 251 Thermal Arc Fabricator User Manual

Page 36

Advertising
background image

FABRICATOR 251

INSTALLATION

3-14

Manual No. 0-4847

3.16 Polarity Changeover

WARNING

ELECTRIC SHOCK CAN KILL! Make certain the input power is disconnected from the power supply before
proceeding. Do not reattach the input power until told to do so in these instructions.

The output terminals are located on the front panel of the welding power source.

CABLE TO GUN, CABLE TO WORK

CABLE TO GUN

CABLE TO WORK

1. GMAW* – Steel, Stainless Steel,
Aluminum & gas shielded Flux
Cored electrode wires

1. D.C. Electrode Positive
(DCEP) – Reverse Polarity

1. Connected to (+)
Pos. output
terminal

1. Connected to (-)
Neg. output
terminal

2. FCAW* – Gasless Flux Cored
electrode wire

2. D.C. Electrode Negative
(DCEN) – Straight Polarity

2. Connected to (-)
Neg. output
terminal

2. Connected to (+)
Pos. output
terminal

CABLE CONNECTIONS

PROCESS

POLARITY

* Exception - Contact your filler metal supplier for the recommended polarity.

Table 3-3: Process Cable Connections

Work Lead

Art # A-07163

Connected for D.C.
Electrode Positive
(DCEP) Welding

Figure 3-14: Polarity Connections for DCEP