Fabricator 251 – Tweco 251 Thermal Arc Fabricator User Manual

Page 42

Advertising
background image

FABRICATOR 251

OPERATION

4-4

Manual No. 0-4847

0

100

200

300

400

500

600

700

800

900

25

50

75

100

125

150

175

200

225

250

275

300

325

Current (Amps)

Wi

re Speed (IPM)

(.030 - AL)(.035 - AL)

(.047 - AL)

Art # A-07453

ALUMINUM

Figure 4-5: Aluminum - AMP to IPM Conversion

Thermal Overload

The critical components for thermal protection are the rectifier stack and the transformer, which are fitted with
thermal overload cut out devices. If the overload is activated then the machine should be left to cool for approxi-
mately 15 minutes before resuming welding. If the Power Source is operated within its duty cycle, the thermal
overload will not activate. Refer to section 2.09 for an explanation of duty cycle and section 2.10 for the power
supply specifications.

Wirespeed Control

The Wirespeed Control knob controls the welding current via the electrode wire feed rate, i.e. the speed of the wire
feed motor.

Coarse Voltage Control Switch

The Coarse Voltage Control sets the voltage level to the welding terminals as it is rotated in either direction. Clock
wise to increase.

Fine Voltage Control Switch

The Fine Voltage Control switch increases the voltage (in smaller increments than the Coarse switch) as it is
rotated in either direction. Clock wise to increase.

CAUTION

The Coarse & Fine Voltage Control switches MUST NOT BE SWITCHED during the welding process.