5.05 Power Supply Problems

FAULT CAUSE

REMEDY

A. Indicator light is ON but welding

arc can not be established.

1. Power On/Standby switch

in standby position.

a. Switch the power On/Standby

switch to the “On” position .

1. Primary fuse is blown.

a. Replace primary fuse.

B. Mains supply voltage is ON.

Indicator light is not lit and
welding arc can not be
established.

2. Broken connection in

primary circuit.

a. Have an Accredited Thermal Arc

Service Agent check primary
circuit.

C. Mains indicator light is not lit

but welding arc can be
established.

1. Indicator light is open

circuit.

a. Have an Accredited Thermal Arc

Service Agent replace Indicator
light.

D. Mains supply voltage is ON and

Indicator light is lit but when the
gun trigger switch is depressed
nothing happens.

1. Gun trigger switch leads

are disconnected.

a. Reconnect.

1. Electrode wire stuck in

conduit liner or contact tip
(burn-back jam).

a. Check for clogged / kinked MIG

Gun conduit or worn contract
tip. Replace faulty
component(s).


E. Mains supply voltage is ON, no

wire feed but gas flows from the
MIG Gun when the gun trigger
switch is depressed.

2. Faulty control PCB or

Tweco Gun

a. Have an Accredited Thermal Arc

Service Agent investigate the
fault.

F. Wire feeds when the gun trigger

switch is depressed but arc can
not be established.

1. Poor or no work lead

connection.

a. Clean work clamp area and

ensure good electrical contact.

G. Wire continues to feed when the

gun trigger switch is released.

1. The Weld Mode Switch has

been set to 4T (latch
operation).

a. Set the Weld Mode Switch to 2T

(normal operation).

1. Worn or dirty contact tip

a. Replace

2. Worn feed roll

a. Replace

3. Excessive back tension

from wire reel hub roll.

a. Reduce brake tension on spool

hub

4. Worn, kinked or dirty

conduit liner

a. Clean or replace conduit liner




H. Jerky wire feed

5. Low Swing Arm pressure

a. Increase the Swing Arm

pressure.

1. Gas hose is cut or pinched

a. Check hose and replace or

repair.

2. Gas passage contains

impurities

a. Disconnect gas hose from the

rear of Fabricator then raise gas
pressure and blow out the
impurities.

3. Gas regulator turned off

a. Turn on.





I. No gas flow

4. Gas cylinder is empty

a. Check cylinder volume and

replace or refill as needed.

J. Gas flow continues after the gun

trigger switch has been
released.

1. Gas valve has jammed

open due to impurities in
the gas or the gas line.

a. Have an Accredited Thermal Arc

Service Agent repair or replace
gas valve.

Table 5-4: Power Supply Problems