Quick fixed automation direct plug torches – Tweco QFW600 User Manual

Page 12

Advertising
background image

quick fixed automation direct plug torches

4-8

SM-QFDP

inStAllAtion AnD oPeRAtion

SECTION 4:

MAINTENANCE

Contact tips and nozzles should be cleaned frequently. Spatter buildup may cause bridging between nozzle and tip. This

could cause electrical shorting between the nozzle and work piece as well as restricting gas flow.
Regularly inspect the conductor tube, torch and cable assembly for abrasions, cuts, and undue wear. Replace or repair

any parts as needed.
The torch and conductor tube assemblies have o-rings for seals. Lubrication of these o-rings should be done periodically

and periodical inspections should be made to ensure that the o-rings do not de-grade, allowing water and/or shielding

gas leaks to occur. When removing the conductor tube from the torch assembly, be sure the single o-ring located in

the bottom of the hole remains in place.

Problem

Possible Cause

Corrective Action

Wire feed

inconsistent or

not smooth.

1. Loose drive Rollers on feeder.

1. Tighten drive rollers.

2. Dirty or plugged conduit.

2. Replace conduit.

3. Conduit pulled back from diffuser.

3. Reposition conduit and tighten front

screw.

4. Sharp bends or kinks in conduit.

4. Remove and replace conduit.

5. Machine improperly adjusted.

5. Reset machine per machine and wire

manufacturers’ recommendations.

6. Spatter buildup on end of contact tip.

6. Clean or replace contact tip.

7. Loose contact tip or diffuser.

7. Tighten contact tip and diffuser pliers

tight.

8. Excessively worn contact tip.

8. Replace contact tip.

9. Loose ground cable or ground clamp.

9. Tighten or replace as required.

Torch assembly

is running hot.

1. Loose power connection.

1. Inspect complete torch and cable for loose

connections and tighten.

2. Loose or undersize ground cable or ground

clamp.

2. Tighten or replace as required.

3. Conductor tube not tight in torch block.

3. Tighten stainless setscrew in torch block.

4. Loose contact tip or diffuser.

4. Tighten contact tip and diffuser.

5. Operating torch and conductor tube assembly

above recommended amperage rating.

5. Readjust machine to correct setting for size

of torch being used.

6. Restricted water flow (only QRW and QRWA

series torch).

6. Inspect water lines for any excessive

bends.

Porous weld.

1. Poor or improper gas flow.

1. Check gas flow out of conductor tube

nozzle. Check for leaks or restrictions in

gas hoses and connections.

2. Moisture from torch/conductor tube.

2. Check o-rings on conductor tube and

torch block. Check the torch block for any

scarring, gouges to the surface.

3. Dirty or contaminated wire.

3. Change wire.

4. Base metal contamination.

4. Replace base metal.

Advertising