3-8
Quick fixed automation series torches
SM-QFTORCH
INSTALLATION AND DISASSEMBLy
CAUTION
Operating a water-cooled torch and cable
assembly without water or restricted flow will
result in damage to the cable assembly.
24. The torch and cable assembly s furnshed wth a purge
hose than can be used to supply nert gas and or ant-
spatter through the torch block and conductor tube
assembly. To use ths purge hose, remove the plastc
plug and connect accordngly.
25. The torch s now ready to place nto operaton.
3.02 Disassembly
1. To dsassemble the torch and cable assembly from the
fixture, reverse the steps noted n Secton 3.01.