Thrust bearing adjustment, Danger – Viking Pump TSM110.2: Heavy Duty LV3900 User Manual

Page 5

Advertising
background image

SECTION TSM

110.2

ISSUE

C

PAGE 5 OF 6

graphite to aid assembly. A length of pipe or tubing will

help to install and seat each packing ring. Install packing

gland, capscrews, and nuts. Make sure gland is installed

square and nuts are tightened evenly. Tighten nuts until

packing gland is snug against packing.

6. Slide the inner spacer collar over the shaft with recessed

end facing rotor.

7. Install the lip seal (lip toward end of shaft) in the bearing

housing and turn the bearing housing into the bracket.

8. Pack the ball bearing with grease, place on the shaft and

push or drive into place in the housing.

9. Install the lip seal (with lip toward end of shaft) and

bearing spacer collar in the outer end cap and turn the

end cap into the bearing housing until tight against the

bearing. Lock in place with two set screws in the flange

of the bearing housing.

10. Put lockwasher and locknut on shaft. Insert length of

hardwood or brass through port opening between rotor

teeth to keep shaft from turning. Tighten locknut to 100-

130 Ft. - lbs. Torque. Bend one tang of lockwasher into

slot of locknut. If tang does not line up with slot, tighten

locknut until it does. Failure to tighten locknut or engage

lockwasher tang could result in early bearing failure and

cause damage to pump.

Remove length of hardwood or brass from port opening.

3. Tighten the two self locking type “Allen” set screws “A” in

the outboard face of the bearing housing with equal force

against the bracket. Your pump is now set with standard

end clearances and locked.

NOTE: Be sure the shaft can rotate freely. If not, back off

additional notches and check again.

4. High viscosity liquids require additional end clearances.

The amount of extra end clearance depends on the amount

of the liquid pumped. For specific recommendations,

consult the factory. Each additional ¼” on the outside

diameter of the bearing housing is equivalent to an extra

end clearance of .001”.

FIGURE 5

FIGURE 4

BALL BEARING

SETSCREW

BEARING HOUSING

SPACER COLLAR

SHAFT

CLOSURE

ENDCAP

SETSCREW

HALF ROUND RINGS

BUSHING

LIPSEAL

IDLER

IDLER DISC

FIGURE 3

THRUST BEARING ADJUSTMENT

See Fig. 5

1. Loosen the two set screws “A” in the outer face of the

bearing housing “B” clockwise until it cannot longer be

turned by hand. Back off counter clockwise until the

rotor shaft can be turned by hand with a slight noticeable

drag.

2. For standard end clearance, back off the thrust bearing

assembly “B” 1.25” length measured on the outside of

the bearing housing.

DANGER

BEFORE STARTING PUMP, BE SURE ALL

DRIVE EQUIPMENT GUARDS ARE IN PLACE.

FAILURE TO PROPERLY MOUNT GUARDS MAY

RESULT IN SERIOUS INJURY OR DEATH.

Advertising