8. Apply a generous amount of non-detergent SAE

30 weight oil to the large diameter of the shaft, the

tapered installation sleeve and the inner diameter of the

mechanical seal rubber parts.

9. Slide

the rotary member, lapped contact surface facing

away from the spring, over the installation sleeve on the

shaft until it is against the spring.
Do not compress the spring.

10. Lubricate the outer diameter of mechanical seal O-ring

seat gasket and flush the lapped seal faces with non-

detergent SAE 30 weight oil.

FIgURE 15

(LEFT SIDE OF PUMP)

ACCESS HOLE FOR TIgHTENINg

SETSCREWS IN SET COLLAR

SPRINg ADAPTER

MECHANICAL SEAL

(ROTARY MEMBER)

SEAL

HOLDER

PLATE

SEAL SEAT gASKET

SEAL HOLDER

SET COLLAR

SEAL SEAT

4. Using a .010 to .015 inch head gasket, install the head

and idler assembly on the pump. Pump head and casing

were marked before disassembly to ensure proper

reassembly. If not, be sure the idler pin, which is offset in

the pump head, is positioned toward and equal distance

between the port connections to allow for proper flow of

liquid through the pump.
If the pump is equipped with a jacketed head plate, install

at this time with a new gasket.
Tighten the head capscrews evenly.

5. Examine the set collar to be sure there are no burrs

or scratches and that the setscrews are withdrawn

so the shaft will not be scratched when the set collar

is installed.

6. Place the seal set collar on the shaft, push into the

seal chamber so the centerline of the setscrew coincides

with the centerline of the access hole on the left side of

the bracket (viewed from the shaft end).

Refer to Figure

15. Tighten the setscrews to secure the set collar to the

shaft.

7. Slide

the spring over the shaft into the seal chamber on

the set collar pilot. Place the tapered installation sleeve

on the shaft.

Refer to Figure 10, page 9.

11. Press the stationary seal seat in the bore until the

back, unlapped face, is just inside the bore. Position

the stationary seal seat by the installing seal holder

and secure the seal holder to the machined face of the

bracket with the seal holder plate.

12. Tighten the nuts securing the seal holder plate evenly so

the seal holder will not be distorted.

13. Remove the tapered installation sleeve.
14. Slide the inner bearing spacer collar over the shaft with

the recessed end facing the rotor.
Place the pair of half round rings on the shaft and slide

the inner bearing spacer collar over the half round rings

to lock them in place.

Refer to Figure 6, page 5.

15. Press the lip seal, lip facing the end of the shaft, in the

inner end cap and insert the end cap through the shaft

end of the bracket. Turn the end cap clockwise, looking

at the shaft end, until it engages the threads. End cap

spanner wrench holes must be facing the rotor. Turn the

end cap with a spanner wrench until it projects slightly

from the opening on the side of the bracket.
The end cap must not be turned so far that the lip seal

drops off the end of the spacer collar on the shaft or the

end cap becomes disengaged from the threads.

Refer

to Figure 6, page 5.
If this happens, remove the inner spacer collar, half

round rings and end cap and start over at Step 15.

16. Pack the ball bearing with multi-purpose grease, NLGI

#2. Place on the shaft and push or gently drive into place

in the bracket.

Install

the outer spacer collar.

17. Press the lip seal, lip facing the end of the shaft, in the

outer end cap and insert the end cap in the bracket. Turn

the end cap in bracket until it is tight against the bearing.

Refer to Figure 6, page 5.

18. Insert a length of hardwood or brass through the port

opening between the rotor teeth to keep the shaft from

turning. Put the lockwasher and locknut on the shaft,

tighten and bend the tang of the lockwasher into the slot

of the locknut.

19. Adjust the pump end clearance. Refer to Thrust

Bearing Adjustment, page 14.

20. Lubricate all grease fittings with multi-purpose grease,

NLGI #2.

DANgER !

Before starting pump, be sure all drive

equipment guards are in place.
Failure to properly mount guards may

result in serious injury or death.