Technical service manual, Important, Pressure adjustment – Viking Pump TSM212: H-LL 724/4724 User Manual

Page 9

Advertising
background image

SECTION TSM 212
PAgE

9 Of 9

ISSUE

f

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

In ordering parts for relief valve on head, always be sure

to give Model and Serial Number of pump as it appears on

name plate and the name of the part wanted. When

ordering springs, be sure to give the pressure setting

desired.

IMPORTANT

CAUTION: Do not run with valve in full bypass for more than

30 seconds at a time. If a new spring is installed or if pressure

setting of pressure relief valve is to be changed from that

which the factory has set, the following instructions must be

carefully followed.
1. Install a pressure gauge in discharge line for actual

adjustment operation.

2. Carefully remove valve cap which covers adjusting

screw.
Loosen locknut which locks adjusting screw so pressure

setting will not change during operation of pump.

3. Turn adjusting screw in to increase pressure and out to

decrease pressure.

4. With discharge line closed at a point beyond pressure

gauge, gauge will show maximum pressure valve will

allow while pump is in operation.

PRESSURE ADJUSTMENT

fIgURE 12

VALVE - LIST Of PARTS

1. Valve Cap

6. Valve Body

2. Adjusting Screw

7. Spring

3. Lock Nut

8. Poppet

4. Spring Guide

9. Cap Gasket

5. Bonnet

10. Bonnet Gasket

HEAVY-DUTY BRACKET MOUNTED PUMPS

SERIES 724 AND 4724

SIZES H - HL

Advertising