PAGE 9 OF 10

When installing the bushings, extreme care must be taken

to prevent breaking. The additional precautions listed below

must be followed for proper installation:

• A press must be used for installation.
• Use Loctite® #4203 or #411 on the outside of the bushing

to hold the bushing in the housing.

• Be certain that the bushing is straight. The groove in the

bushing should line up with the groove in the casing.

• Do not stop the pressing operation until the bushing is in

the proper position; starting and stopping may result in a

cracked bushing.

• Check the bushing for damage after installation.

INSTALLATION OF PEEK® BUSHINGS

PEEK

®

is a trademark of Victrex PLC

Loctite® is a trademark of Henkel Consumer Adhesives, Inc.

DANGER!

Before starting pump, be sure all drive equipment

guards are in place.

Failure to properly mount guards may result in seri-

ous injury or death.

DANGER!

Failure to Follw the above listed precautionary

measures may result in serious injury or death.