3 lip-seal setting distances, 4 lubricants, 5 material specification – Viking Pump TSM288: SL Series Lobe Pumps User Manual

Page 33: 6 trouble shooting

Advertising
background image

fIGURE 128

SECTION TSM 288

ISSUE

A

PAGE 33 OF 36

6.3 lIP-sEal sETTING

dIsTaNCEs

Pump

Model

dimension

“X” (mm)

dimension

“X” (inch)

SLAS

4

0.16

SLBL

6

0.24

SLCS

5

0.20

SLDL

6

0.24

SLES

3

0.12

SLFL

8

0.31

SLGS

7

0.28

6.4 lUbRICaNTs

The recommended lubricant for use in the SL Series is an

EP00 grade, lithium based, extreme pressure grease intended

for ‘sealed for life’ units. Suitable for operating temperatures

between –30°C and 120°C (-22°F to 266°F) and a base

viscosity in the region of 200 cSt at 40°C (104°F).
The unit is shipped as standard with the recommended grade

listed above. Refer to manufacturers recommended operating

conditions concerning limitations, servicing and application. In

case of doubt, please consult the factory for details.
SLA = 0.25 Liters .......... (0.066 US gallons)

SLB = 0.7 Liters ............ (0.184 US gallons)

SLC = 1.1 Liters ............ (0.29 US gallons)

SLD = 2.2 Liters ............ (0.58 US gallons)

SLE = 4.6 Liters ............ (1.21 US gallons)

SLF = 8.2 Liters ............ (2.16 US gallons)

SLG = 12 Liters ............ (3.16 US gallons)
During the filling operation, lubricant should be directed at the

front bearings to ensure good circulation and coverage in this

area.
Care should be taken not to overfill the gearbox.

6.5 MaTERIal sPECIfICaTION

Rotors ............................ 316L Stainless Steel

Casing ........................... 316L Stainless Steel

Shafts ............................ 316L Stainless Steel

Head .............................. 316L Stainless Steel

Rotor Retainer ............... 316L Stainless Steel

Bearing Housing ............ Grade 220 Grey Cast Iron, Coated

No

flow

Irregular

flow

Under Capacity

Pump Overheats

Motor Overheats

Excessive Rotor W

ear

Excessive

seal W

ear

Noise / V

ibration

seizure

Pump

stalls on

startup

Causes

action

Incorrect Direction of Rotation

Reverse Motor

Pump Not Primed

Expel Gas From Suction Line / Pump Chamber & Prime

Insufficient NPSH Available

Increase Suction Line & Static Suction Head Diameter. Simplify Suction

Line & Reduce Length. Reduce Pump Speed & Product Temperature

Product Vaporizing in Suction Line
Air Entering Suction Line

Remake Pipework Joints

Gas in Suction Line

Expel Gas From Suction Line / Pump Chamber

Insufficient Static Suction Head

Raise Product Level to Increase Static Suction Head

Product Viscosity Too High

Decrease Pump Speed / Increase Product Temperature

Product Viscosity Too Low

Increase Pump Speed / Increase Product Temperature

Product Temperature Too High

Cool Product / Pumping Chamber

Product Temperature Too Low

Heat Product / Pumping Chamber

Unexpected Solids in Product

Clean System / Fit Strainer on Suction Side of Pump

Discharge Pressure Too High

Check for Blockages / Simplify Discharge Line

Casing Strained by Pipework

Check Pipe Alignment / Support Pipework

Pump Speed Too High

Decrease Pump Speed

Pump Speed Too Low

Increase Pump Speed

Seal Flush Inadequate

Increase Seal Flush to Required Pressure / Flow

Bearing / Timing Gear Wear

Replace Worn Components

6.6 TROUblE sHOOTING