Special information, Installation, Danger – Viking Pump TSM340.1: SG-10, SG-14 User Manual

Page 3

Advertising
background image

SECTION TSM

340.1

ISSUE

D

PAGE 3 OF 11

SPECIAL INFORMATION:

DANGER !

Before opening any Viking pump liquid cham-

ber (pumping chamber, reservoir, relief valve

adjusting cap fitting etc.) Be sure:

1. That any pressure in the chamber has

been completely vented through the suction or

discharge lines or other appropriate openings

or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or made

non- operational so that it cannot be started

while work is being done on pump.

3. That you know what liquid the pump has

been handling and the precautions necessary

to safely handle the liquid. Obtain a material

safety data sheet (MSDS) for the liquid to be

sure these precautions are understood.

Failure to follow above listed precautionary

measures may result in serious injury or death.

INSTALLATION:

GENERAL:
The following items must be considered prior to pump

installation:
1. Location - locate the pump as close as possible to

supply of liquid being pumped. If possible locate pump

below liquid supply. Viking pumps are self-priming; but,

the better the suction conditions the better the pump will

perform.

2. Accessibility - pump must be accessible for inspection,

maintenance and repair.

3. Suction/Discharge - SG Series pumps are designed for

clockwise rotation as standard (viewed from end of shaft).

ROTATION: Viking external gear pumps can be offered in

a clockwise (-G0) or counter clockwise (-G1) rotation. The

intended rotation and inlet / outlet port positions are noted on

the pump nameplate. Do not run the pump in reverse, or the

seal will be exposed to full discharge pressure.
PRESSURE RELIEF VALVES:
1. Viking pumps are positive placement pumps and must be

provided with some sort of pressure protection. This may

be a relief valve mounted directly on the pump, an inline

pressure relief valve, a torque limiting device or a rupture

disk.

2. Relief valve adjusting screw cap must always point

towards suction side of pump.

3. Pressure relief valves cannot be used to control pump

flow or regulate discharge pressure.

For additional information on pressure relief valves, refer to

Technical Service Manual TSM000 and Engineering Service

Bulletin ESB-31.
MOUNTING:
1. Surfaces pump mounts against must be clean and flat.
2. For NEMA Mount, use SAE Grade 5 or better capscrews

to mount pump.

For IEC Mount, use Class 8.8 or better capscrews to

mount pump.

3. Standard SG Series pumps are designed to be used

with jaw type couplings that do not induce axial thrust on

the pump shaft. If an improper type of coupling is used,

internal damage may result.

4. Do not strike or press the pump drive coupling to install.

Internal pump damage will result. If the coupling does not

slide onto the shaft, inspect the coupling, shaft and key for

nicks or burrs and remove.

5. If the pump is to be belt or gear driven, the overhung load

option must be specified.

6. Once the pump has been mounted and the coupling

installed, it is recommended to put lube oil into the suction

port and turn the pump by hand to make sure it turns freely.

ALIGNMENT:
Check alignment after mounting.
1. If unit has flexible coupling, remove any coupling guards or

covers and check alignment of coupling halves. A straight

edge (piece of key stock will work) across coupling must

rest evenly on both rims at top, bottom and sides. See

Figure 1.

2. Make final check on alignment after piping is hooked up.

DANGER!

Before starting the pump, be sure all drive

equipment guards are in place.
Failure to properly mount guards may result in

serious injury or death.