Technical service manual, Pressure adjustment important, Assembly – Viking Pump TSM445: LVP Vane Pumps User Manual

Page 11

Advertising
background image

SECTION TSM 445
PAgE

11 Of 11

ISSUE

C

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

© 3/2013 Viking Pump Inc.

All rights reserved

TECHNICAL SERVICE MANUAL

WARRANTY

Viking warrants all products manufactured by it to be

free from defects in workmanship or material for a

period of one (1) year from date of startup, provided

that in no event shall this warranty extend more than

eighteen (18) months from the date of shipment from

Viking. The warranty period for Universal Seal series

pumps ONLY (Universal Seal models listed below) is

three (3) years from date of startup, provided that in

no event shall this warranty extend more than forty-two

(42) months from the date of shipment from Viking.
UNDER NO CIRCUMSTANCES SHALL VIKING BE

LIABLE UNDER THIS WARRANTY OR OTHERWISE

FOR SPECIAL, INCIDENTAL, INDIRECT,

CONSEQUENTIAL OR PUNITIVE DAMAGES OF ANY

KIND, INCLUDING, BUT NOT LIMITED TO, LOST

OR UNREALIZED SALES, REVENUES, PROFITS,

INCOME, COST SAVINGS OR BUSINESS, LOST OR

UNREALIZED CONTRACTS, LOSS OF GOODWILL,

DAMAGE TO REPUTATION, LOSS OF PROPERTY,

LOSS OF INFORMATION OR DATA, LOSS OF

PRODUCTION, DOWNTIME, OR INCREASED

COSTS, IN CONNECTION WITH ANY PRODUCT,

EVEN IF VIKING HAS BEEN ADVISED OR PLACED

ON NOTICE OF THE POSSIBILITY OF SUCH

DAMAGES AND NOTWITHSTANDING THE FAILURE

OF ANY ESSENTIAL PURPOSE OF ANY PRODUCT.
THIS WARRANTY IS AND SHALL BE VIKING’S SOLE

AND EXCLUSIVE WARRANTY AND SHALL BE IN

LIEU OF ALL OTHER WARRANTIES, EXPRESS

OR IMPLIED, INCLUDING, BUT NOT LIMITED

TO, ALL WARRANTIES OF MERCHANTABILITY,

FITNESS FOR A PARTICULAR PURPOSE AND

NON-INFRINGEMENT ALL OF WHICH OTHER

WARRANTIES ARE EXPRESSLY EXCLUDED.
See complete warranty at www.vikingpump.com.

PRESSURE ADJUSTMENT

IMPORTANT

DANgER !

Before starting pump, be sure all drive

equipment guards are in place.
failure to properly mount guards may

result in serious injury or death.

ASSEMBLY

Reverse the procedures outlined under

“Disassembly,”

page 10. If the valve is removed for repairs, be sure to

replace in the same position. The relief valve adjusting screw

cap must always point towards the suction side of the pump.

If pump rotation is reversed, remove the relief valve and turn

end for end.

If a new spring is installed or if pressure setting of the

pressure relief valve is to be changed from that which the

factory has set, the following instructions must be carefully

followed.
1. Carefully remove the valve cap that covers the adjusting

screw.

2. Loosen the locknut that locks the adjusting screw so

the pressure setting will not change during operation of

the pump.

3. Install a pressure gauge in the discharge line for the

actual adjusting operation.

4. Turn

the adjusting screw in to increase the pressure and

out to decrease the pressure.

5. To test the valve setting, slowly close the line valve on

the downstream side of the pump until the pressure

relief valve opens and flow through the pump stops. This

will show the maximum discharge pressure the valve

allows at the current setting. Limit the amount of time

in this condition to prevent overheating of the pump due

to internal recirculation of the liquid.

In ordering parts for the pressure relief valve, always

give the model number and serial number of the pump

as it appears on the nameplate and the name of the part

wanted. When ordering springs, be sure to give the pressure

setting desired.

LVP SERIES VANE PUMPS

SERIES LVP STAINLESS STEEL

SIZES 01, 02, 05, 08, 19 AND 23

Advertising