Assembly – Viking Pump TSM630.2: LS-QS Universal Seal User Manual

Page 5

Advertising
background image

SECTION TSM 630.2

ISSUE

I

PAGE 5 OF 12

FIGURE 5

LS BEARING HOUSING ASSEMBLY

FIGURE 6

Q-QS BEARING HOUSING ASSEMBLY

7. Carefully remove rotor and shaft to avoid damaging

bracket bushing.

8. Loosen two radial setscrews in flange of bearing housing

and with a spanner wrench remove the outer end cap

with closure and outer bearing spacer collar.

9. Remove the double row ball bearing, (2 tapered roller

bearings on “Q” and “QS” sizes), closure and inner

bearing spacer collar from the bearing housing.

10. Clean all parts thoroughly and examine for wear and

damage. Check lip seals, bearings, bushings, and idler

pin and replace if necessary. Check all other parts for

nicks, burrs, excessive wear and replace if necessary.

Wash bearings in clean solvent. Blow out bearings with

compressed air. Do not allow bearings to spin; turn

them slowly by hand. Spinning bearings will damage

bearing components. Make sure bearings are clean,

then lubricate with light oil and check for roughness.

Roughness can be determined by turning outer race by

hand.

CAUTION: Do not intermix inner and outer races of tapered

roller bearing (“Q” and “QS sizes).
11. Casing can be checked for wear or damage while

mounted on bracket.

12. Inspect bracket bushing for wear and remove if damaged

or worn.

1. Install bracket bushing. If bracket bushing has a

lubrication groove, install bushing with groove at 6.00

o’clock position in bracket. If carbon graphite,

Refer to

Installation of Carbon Graphite Bushings, page 9.

2. Coat shaft of rotor shaft assembly with light oil. Start

end of shaft in bracket bushing turning from right to left,

slowly pushing rotor in casing.

3. Coat idler pin with light oil and place idler and bushing

on idler pin in head. If replacing with carbon graphite

bushing,

Refer to Installation of Carbon Graphite

Bushings, page 9.

4. Using a .010 to .015 inch thick head gasket, install head

and idler assembly on pump. Pump head and casing

should have been marked before disassembly to insure

proper reassembly. If not, be sure idler pin, which is

offset in pump head, is positioned toward the equal

distance between port connections to allow for proper

flow of liquid through pump.
Refer to Figure 5 and 6 for bearing housing assembly.

5. Install the lipseal in the bearing housing (See the

appropriate figure for lip orientation).

6. “LS” Pumps: Pack the ball bearing with grease and

push or press the bearing into the bearing housing.

Refer to Figure 5.
“Q” and “QS” Pumps:
Pack tapered roller bearings

with grease and press or push bearings into housing with

large end of inner races together. It is possible to install

bearings incorrectly. For proper assembly see Figure 6.

7. Install the lipseal in the end cap (see appropriate figure

for lip orientation). Thread the end cap into the bearing

housing along with outer bearing spacer collar and

tighten against the bearing.

ASSEMBLY

TAPERED ROLLER BEARING

BALL BEARING

BEARING HOUSING

SETSCREW

SPACER COLLAR

SHAFT

LIPSEAL

END CAP

HALF ROUND RINGS

BRACKET

SETSCREW

BEARING HOUSING

SPACER COLLAR

SHAFT

LIPSEAL

END CAP

LIPSEAL

SETSCREW

SPACER

COLLAR

SETSCREW

Advertising