SECTION TSM 635.2
PAGE

1 Of 12

ISSUE

E

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

VIKING PUMP, INC.

A Unit of IDEX Corporation

Cedar Falls, IA 50613 USA

TECHNICAL SERVICE MANUAL

WARNING!

Persons with surgical implants of a metallic

or electronic nature should avoid working on

pump – especially the inner magnet assembly.
This information must be read fully before

beginning any maintenance or repair of the

pump. All maintenance or repair must be

done by SUITABLY TRAINED or qualified

persons only.

FIGURE 1

MoDEL LS8124A-325

CoNTENTS

INTRoDUCTIoN

The illustrations used in this manual are for identification

purposes only and cannot be used for ordering parts. Obtain

a parts list from the factory or a Viking® representative.

Always give the complete name of a part, the part number

and material, along with the model number and serial number

of the pump when ordering repair parts. The unmounted

pump or pump unit model number and serial number can be

found on the nameplate secured to the pump.
This manual refers only with Series 8124A, 8123A and 8127A

universal magnetic drive pumps. Refer to Figures 1 through

17 for general configuration and nomenclature used in this

manual. Pump specifications and recommendations are

listed in Catalog Section 635.
In the Viking model number system, the basic size letters (K,

KK, L, etc.) are combined with the series number (8124A,

8123A, 8127A) indicating basic pump external construction

material, see

Figure 3.

Introduction . . . . . . . . . . . . . . . . . . . . . . . .

1

Special Information . . . . . . . . . . . . . . . . . . . .

1

Safety Information. . . . . . . . . . . . . . . . . . . . .

2

Maintenance . . . . . . . . . . . . . . . . . . . . . . .

3

Model Number System . . . . . . . . . . . . . . . . . .

3

Parts Identification Drawings . . . . . . . . . . . . . . .

4

Disassembly of Pump. . . . . . . . . . . . . . . . . . .

5

Disassembly / Assembly of Bracket Bearings. . . . . . .

6

Installation of Bushings . . . . . . . . . . . . . . . . . .

7

Assembly of Pump . . . . . . . . . . . . . . . . . . . .

7

Pump Rotation . . . . . . . . . . . . . . . . . . . . . .

9

Adjusting End Clearance . . . . . . . . . . . . . . . . .

9

Pressure Relief Valve Instructions . . . . . . . . . . .

10

Troubleshooting . . . . . . . . . . . . . . . . . . . . .

11

Warranty . . . . . . . . . . . . . . . . . . . . . . . .

12

SPECIAL INFoRMATIoN

DANGER !

Before opening any Viking pump liquid cham-

ber (pumping chamber, reservoir, relief valve

adjusting cap fitting etc.) Be sure:

1. That any pressure in the chamber has been

completely vented through the suction

or discharge lines or other appropriate

openings or connections.

2. That the driving means (motor, turbine,

engine, etc.) has been “locked out” or made

non- operational so that it cannot be started

while work is being done on pump.

3. That you know what liquid the pump has been

handling and the precautions necessary to

safely handle the liquid. obtain a material

safety data sheet (MSDS) for the liquid to be

sure these precautions are understood.

Failure to follow above listed precautionary

measures may result in serious injury or death.

ROTATION: Viking Mag Drive® pumps are designed to run

in either direction. See

“Pump Rotation”, page 9.

PRESSURE RELIEF VALVES:
1. Viking pumps are positive displacement pumps and

must be provided with some sort of pressure protection.

This may be a relief valve mounted directly on the pump,

an inline pressure relief valve, a torque limiting device or

a rupture disk. Do not rely on decoupling of magnets for

protection from over pressure; this may result in damage

to the magnets, pump, or other equipment.

Electronic copies of the most current TSM issue can be found on the Viking Pump website at www.vikingpump.com

SERIES 8124A, 8123A, 8127A

SIZES K, KK, L, LQ, LL, and LS

UNIVERSAL MAG DRIVE PUMPS

Advertising