SECTION TSM 710.1

ISSUE

C

PAGE 6 OF 8

MeCHANiCAL SeAL

DANger !

before starting the pump, be sure all drive

equipment guards are in place.

failure to properly mount guards may

result in serious injury or death.

For disassembly, see

“DiSASSeMbLy” on page 4.

For assembly, see

“ASSeMbLy” on page 4.

NOTe: Never touch the mechanical seal faces with anything

except clean hands or a clean cloth. Minute particles can

scratch the seal faces and cause leakage.
Always clean the rotor and shaft and seal housing bore

before installing the mechanical seal. Make sure surfaces

are clean and free of scratches.
There are two available mechanical seals. The standard

features a cup type seat. A “pin style” seal is also available

that has the seal seat pinned to prevent rotation. This design

is used for viscosities higher than 750 cPs.

THruST beAriNg ADJuSTMeNT

See

figure 4 on page 3.

1. Loosen the two setscrews in the outer face of the

bearing housing and turn the thrust bearing assembly

clockwise until it can no longer be turned by hand. Back

off counterclockwise until the rotor shaft can be turned

by hand with a slight, noticeable drag.

2. For standard end clearance, back off the thrust bearing

assembly the required length as measured on the outside

diameter of the bearing housing

(See Table 3).

3. Tighten the two self locking type “Allen” setscrews in the

outboard face of the bearing housing. Tighten each with

equal force against the bracket. The pump is now set

with standard end clearance.

PuMP

SiZe

STANDArD eND

CLeArANCe

(mm)

LeNgTH ON OD* (mm) fOr

STD.

eACH .025 mm

ADDiTiONAL

HLE

.08

12

4

ATE

.08

15

5

ALE

.08

15

5

* Turn bearing housing CCW this distance to obtain either

standard or additional end clearance.

iNSTALLATiON Of CArbON

grAPHiTe buSHiNgS

When installing Carbon graphite bushings, extreme care

must be taken to prevent breaking. Carbon graphite is a

brittle material and cracks easily. If cracked, the bushing will

quickly disintegrate. Using a lubricant on the bushing and the

mating part will help in installation. The additional precautions

listed below must be followed for proper installation:
1. A press must be used for installation.

2. Be certain the bushing is straight.

3. Do not stop the pressing operation until the bushing is in

the proper position, starting and stopping will result in a

cracked bushing.

4. Check the bushing for cracks after installation.

iNSTALLATiON Of fOOT

Series 4176 pumps come equipped with a removable foot.

Removal of the foot is not normally required for maintenance.

In cases where the foot needs to be replaced or is being

added, use the following steps.
1. Ensure alignment pins are installed in the top of the foot

prior to assembly of the foot to the casing.

2. Match the foot to the casing by inserting pins into the

bottom of the casing.

3. Secure foot to casing using the socket head capscrews

and lock washers. Torque capscrews to 100-110 N•m.

figure 7

TAbLe 3

NOTe: Be sure the shaft rotates freely. If it doesn’t,

repeat the above procedure.

4. High viscosity liquids require additional end clearances.

The amount of extra clearance depends on the viscosity

of the liquid pumped. For specific recommendations,

consult the factory.

Table 3 shows the bearing housing

adjustment required for additional end clearance as well

as values for standard end clearance.

Advertising