4 Operating Guidelines

4.1 Temperature decrease (SETBACK) and

automatic switch-off time (AUTO-OFF) with

connected Switching Tool Stand

The SETBACK time and AUTO-OFF time can be set at the control

unit (WD1, WD2, WD1M, WD2M and WR 3M units), or are

permanently specified (WSD and WRS units).
After placing the soldering tool in the Switching Tool Stand, the

temperature decreases and/or the system shuts down, depending on

the setting at the control unit. The respective switching action is

displayed in the following table.

Tab. 1. Temperature and switch-off action of the control units WD1, WD2, WD1M, WD2M,
Tab. 2. WR 3M, WSD and WRS with different settings of the SETBACK and AUTO-OFF functions

Possible settings at the control

unit

1)

SETBACK time

[1-99 mins]

OFF time

[1-999 mins]

Temperature switching action after placing the soldering tool in the

Switching Tool Stand

0

0

The soldering tool is switched off in the holder

2)

.

ON

0

The soldering tool is regulated in the holder

2)

down to STANDBY

temperature

3)

.

0

Time

The soldering tool is switched off in the holder

2)

after the OFF time

has elapsed.

ON

Time

The soldering tool is regulated in the holder

2)

down to the STANDBY

temperature

3)

and is switched off after the OFF time has elapsed.

Time

0

The soldering tool is regulated in the holder

2)

down to STANDBY

temperature

3)

after the SETBACK time has elapsed.

Time

Time

The soldering tool is regulated in the holder

2)

down to the STANDBY

temperature

3)

after the SETBACK time has elapsed and is switched

off after the OFF time has elapsed.

1)

With the WSD and WMD devices, only the settings 0/0 and ON/TIME are possible, whereby the respective

time values for SETBACK (20 minutes) and AUTO-OFF (60 minutes) are permanently specified. With

these device types, deviating SETBACK times are only possible with the external input device WCB2.

2)

Outside the Switching Tool Stand, the soldering tool always remains at the set specified temperature.

The holder function is activated after the first time the soldering tool is deposited.

3)

The STANDBY temperature must be below the set specified temperature; otherwise the SETBACK

function is inactive.