6 fault messages and corrective actions – Weller WDH 20T User Manual

Page 5

Advertising
background image

WDH 10T / WDH 20T

5-7

Note

Observe the Operating Instructions of your control unit when setting

and switching the SETBACK and AUTO-OFF functions on and off.

4.2 Switching valve control with Switching Tool

Stand on/off (WAD101)

When operating a soldering iron with inert gas and when using the

Switching Tool Stand, the valve control must be set at the WAD 101

control unit. Two switching conditions are possible:

A-1: the valve control is switched on. The valve is activated by the

Switching Tool Stand with the ON/OFF function. In this operating

condition, the SETBACK function "OFF" is not available.

A-0: the valve control is switched off. The SETBACK function is

available without restrictions.

Note

Observe the Operating Instructions of your control unit when

setting the valve control function.

5 WDH 10T / WDH 20T: maintenance and

care

The sponge should be cleaned regularly to remove solder residue

using distilled water only.

6 Fault messages and corrective actions

Message/Symptom

Possible cause

Corrective measures

SETBACK time on the

soldering station is activated

Soldering iron only switches off

after the set time:
Z

Set the SETBACK time on the

soldering station to 0.

Soldering iron does not

switch off after being placed

in the holder

The holder is not correctly

connected

Z

Check connecting cable
- Holder cable to soldering

station

- Soldering iron to holder

Soldering iron no longer

switches on after removal

from holder

Movable funnel or shift linkage

is jammed

Check funnel and shift linkage

Advertising