Weller WD2000M User Manual

Page 10

Advertising
background image

English

88

Select the “FCC” High or Low Set point with the UUPP or

DDOOW

WNN Scroll Key. After the “FCC” function is complete

at both “Set” points, Radio Button 22 is used to exit the
menu.

UUPP Scroll Key: High “Set” point 842°F/450°C

DDOOW

WNN Scroll Key: Low “Set” point 212°F/100°C

RReesseettttiinngg tthhee SSppeecciiaall FFuunnccttiioonnss ttoo FFaaccttoorryy SSeettttiinnggss

Press and hold the 22 Radio Button. Then press the UUPP
and DDOOW

WNN Scroll Keys at the same time. "FFSSEE",

“Factory Setting Enabled” appears in the display. The
station is now reset to its factory default settings.

IIm

mppoorrttaanntt::

TThhee ssoollddeerriinngg ttooooll bbeeccoom

meess hhoott dduurriinngg tthhee FFaaccttoorryy

CCoonnttrrooll CChheecckk.. NNeevveerr lleeaavvee ccoom

mbbuussttiibbllee m

maatteerriiaallss nneeaarr

tthhee hhoott ssoollddeerriinngg iirroonn..

77..22..22 AAddjjuussttiinngg FFaaccttoorryy CCoonnttrrooll CChheecckk SSeettttiinnggss (( FFCCCC ))
CCoonnttrrooll CChheecckk aatt 221122°°FF//110000°°CC
DDeepprreessss tthhee DDOOW

WNN SSccrroollll KKeeyy

The station sets the temperature of the soldering tip to
212°F/100°C. Once the temperature becomes stable (at
which point the indicator flashes), the soldering tip
temperature reading on the external device is compared
to that shown on the station display. If the temperature
readings differ, the UUPP// DDOOW

WNN Scroll Keys can be used

to make adjustments. The temperature Offset is indicat-
ed in the display. A maximum temperature adjustment
of ±72°F/±40°C is possible. After the measured temper-
ature matches that shown on the station display,
depress the Radio Button II--IIII--IIIIII to confirm. The temper-
ature Offset is reset to “0”. This concludes the Factory
Control Check adjustments at 212°F/100°C.

Press Radio Button 2 to exit the menu without saving

any changes.

CCoonnttrrooll CChheecckk aatt 884422°°FF//445500°°CC
DDeepprreessss tthhee UUPP SSccrroollll KKeeyy
The station sets the temperature of the soldering tip to
842°F/450°C. Once the temperature becomes stable (at
which point the indicator flashes), the soldering tip
temperature reading on the external device is compared
to that shown on the station display. If the temperature
readings differ, the UUPP// DDOOW

WNN Scroll Keys can be used

to make adjustments. The temperature offset is indicat-
ed in the display. A maximum temperature adjustment
of ±72°F/±40°C is possible. After the measured temper-
ature matches that shown on the display, depress the
Radio Button II--IIII--IIIIII to confirm. The temperature offset
is reset to 0. This concludes the Factory Control Check
adjustment at 842°F/450°C.

Press Radio Button 22 to exit the menu without saving
any changes.

After both control points, 212°F(100°C) and 842°F
(450°C), have been set and confirmed, the Factory

Control Check process is complete.

77..22..33 SSttaattiioonn CCooddee ((IIDD nnuum

mbbeerr))

When using multiple WD stations, you can assign a
number from 0 - 999 to each soldering station for iden-
tification purposes.

Use the UUPP // DDOOW

WNN Scroll Keys to change the ID num-

ber.
Switch to previous menu item with Radio Button 11.
Switch to next menu item with Radio Button II--IIII--IIIIII.

Radio Button 22 is used to exit Special Functions Menu

842°F /450°C

212°F /100°C

Temperature
Deviation

Advertising
This manual is related to the following products: