66

English

77..11..22 AAuuttoo OOffff TTiim

mee ((““OOFFFF””))

When the soldering tool is not in use, it is automatically
switched off after the “OFF” time has elapsed. The Auto
Off time can be set from 0 – 999 minutes. With a setting
of "0 min", the Auto Off function is disabled. Auto Off is
carried out independently of the Setback function. The
“Read” temperature is displayed (flashing) and may be
monitored as a decreasing heat indicator; "OOFFFF"
appears in the display. Below 122°F ( 50°C ), a flashing
dash appears in the center of the display.

Change the “OFF” time with the UUPP or DDOOW

WNN Scroll Keys.

Switch to previous menu item with Radio Button 11.
Switch to next menu item with Radio Button II--IIII--IIIIII .

77..11..33 TTeem

mppeerraattuurree OOffffsseett

The actual soldering tip temperature can be changed
±72°F/±40°C by the input of a temperature offset. The
Offset function is used to match the station display to
the tip temperature when measured with an external
instrument.

Change the “Offset” value with the UUPP or DDOOW

WNN Scroll

Key.

Switch to previous menu item with Radio Button 11.
Switch to next menu item with Radio Button II--IIII--IIIIII .

77..11..44 SSeettbbaacckk TTiim

mee

If the soldering tool is not being used, the temperature
is decreased automatically to Standby temperature (see
7.1.1) after the specified Setback time has elapsed. The
Setback time, after which the soldering unit switches to
Standby mode, can be set from 0 – 99 minutes. With a
setting of "0 min", the Setback function is switched Off.
The Setback status is indicated by a flashing “Read”
temperature and "SSTTAANNDDBBYY" appears in the display.
Depress the UUPP or DDOOW

WNN Scroll Key to end “Setback”

and return the station to the “Set” temperature.

Change the “Setback” time with the UUPP or DDOOW

WNN Scroll

Key.

Switch to previous menu item with Radio Button 11.
Switch to next menu item with Radio Button II--IIII--IIIIII .

77..11..55 W

Wiinnddoow

w FFuunnccttiioonn

The Window Function allows the temperature to be
adjusted within a range (max. ±180 °F. (±99 °C )), above
and below the Locked temperature (see 7.1.7). The
Locked temperature thus represents the middle of the
settable temperature range.

Note: To utilize the window function, the station has to
first be placed into Lock mode.

Use the UUPP / DDOOW

WNN Scroll Keys to change the range of

temperatures allowed within the operating “window”.

Switch to previous menu item with Radio Button 11..

Advertising