Discharge spout, Truss – Wheatheart WHR 130 x 51-71ft Augers PTO User Manual

Page 23

Advertising
background image

WHEATHEART - GHR & WHR GRAIN AUGERS

3. A

SSEMBLY

GRAIN AUGERS SD

3.7. D

ISCHARGE

S

POUT

30662 R1

23

3.7. DISCHARGE SPOUT

1. Attach

discharge spout with two

7/16" x 1-3/4" bolts and locknuts
(Figure 3.9).

3.8. TRUSS

See Figure 3.10 and Figure 3.11.

Note:

Two 3/8” cable clamps are supplied to secure truss cables to the eyebolts as
described below. All other applications require 5/16” cable clamps.

1. Fasten lower truss anchor to bracket.

• use two 7/16” x 1-1/4” bolts and locknuts.

2. Fasten two truss support brackets to centre tube with two 7/16” x 1-1/4” bolts

and locknuts each (see Figure 3.10 for correct placement).

The 71’ auger requires a high truss support center bracket located between the
two standard support brackets. Fasten with two 7/16” x 1-1/4” bolts and locknuts
(see Figure 3.11
for correct placement).

3. Attach eyebolt to one end of truss cable with two 5/16” cable clamps. Insert

eyebolt into lower truss anchor and thread on nut a short way.

• use a 3/8” cable clamp.

4. Pull truss cable over truss support brackets, around upper truss anchor and

back over truss support brackets to lower truss anchor, holding it loosely in
place with one 5/16” cable clamp at upper truss anchor, and two 5/16” cable
clamps at each truss support bracket.

Important:

Do not tighten cable clamps at this time.

5. The upper end of augers equipped with truss cables should have an upward

bow before being placed on the transport undercarriage (auger tube will
straighten when fully assembled). Place supports under the discharge end
until upward bow is correct.

Figure 3.9

51'

2" (5.08 cm) upward bow

61'

3" (7.62 cm) upward bow

71'

5" (12.7 cm) upward bow