Fan speed, Recommended fan speeds, Marker operation – Great Plains 3N4010HDA Operator Manual User Manual

Page 33: Set selector valve

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

29

2013-09-24

Table of Contents

Index

196-444M

Fan Speed

This information is repeated from the air cart Operator’s
manual, which has additional guidance.

Machine Damage Risk:
Always engage the fan with the tractor at a low engine speed.
Engaging the fan when the tractor is at high speed may cause
fan damage.

Do not reverse hydraulic flow with the fan running.

Fan speed is monitored and reported by the seed
monitor, but is manually controlled. The optimum rate
depends on the seed type and treatments. See “Fan
Speed Adjustment
” in the cart Operator’s Manual for
further information.

The proper reading for the magnehelic air pressure gauge is
12 to 25 inches of water. A sudden drop in pressure is a sign of
a possible leak which can adversely affect seeding.

Marker Operation

Single (left side) or dual markers are optional on the
3N-4010HDA. See “Flat Fold Markers” on page 71 for
ordering information.

Markers share the hydraulic circuit with the Fold circuit.
The selector valve is present to select between Marker
and Fold circuits.

Set Selector Valve

Refer to Figure 26
(front view depicting valve set to Markers)
Before operating markers, make sure the drill is
configured for the planned field operations or marker
maintenance, and the set the drill selector valve to
enable the marker hydraulic circuit.

Recommended Fan Speeds

Seeds

Fan RPM

Sunflowers

2,250 - 3,000

Wheat

3,250 - 4,000

Soybeans

2,750 - 3,500

Milo

3,250 - 4,000

Figure 25

Fan Air Pressure

26425

Figure 26

Drill Selector Valve

21844