Manual s.s.f. entry – Great Plains V-300F Operator Manual User Manual
Page 55

Great Plains Manufacturing, Inc.
Monitor Operation
51
11/15/2007
148-057M-A
Manual S.S.F. Entry
For a typical V300, firm dry ground, nominal wheel slip-
page and new tires inflated to factory specification, the
calculated calibration figure is:
3.235 meters (Metric units mode) or
127.4 inches (Imperial units mode).
Note: The factory default is 2.000 (meters) or 78.78 (inch-
es), and is not correct for the V300/V300F.
To change the S.S.F:
1.
Channel Select
to Forward Speed
.
Press and hold the
to enter Program Mode 1.
The units of measure display (see page 47) appears
for a few seconds. Continue holding the button until a
numeric display appears.
3.
While continuing to hold
, use Channel Select
to select a digit, and then the decimal point.
Continue to hold
to cycle slowly between 0-9
and decimal point positions. Release
at desired
values.
4.
While continuing to hold
, press
again to
select the next display element, and hold to change.
Repeat until the desired value is entered.
5.
Release
to save the new values.
Figure 51
Nominal S.S.F. Value (m)
22632