Hopper level function, Enable / disable hopper level alarm – Great Plains V-300F Operator Manual User Manual
Page 74

70
V300 & V300F
Great Plains Manufacturing, Inc.
148-057M-A
11/15/2007
Hopper Level Function
These functions are for the main seed box and optional
fertilizer compartment only. The monitor has no sensors
for the optional small seeds box.
Refer to Figure 70
When the seed or fertilizer levels drop below the sensor
fitted in the side of the hopper, the instrument defaults to
this channel, sounds 5 beeps, and displays “ALAr”.
Enable / Disable Hopper Level Alarm
1.
Channel Select
to the Level
channel.
Press and hold the
button to enter Program
Mode 1.
The current setting is displayed:
“1” = alarm function enabled
“0” = alarm function disabled.
3.
Continue holding the
button and press
to
select to change the setting.
4.
Release both buttons when done. The instrument
returns to the normal display mode.
Figure 70
Hopper Level Low Alarm
22632
Figure 71
Seed Level Alarm Enabled
22632