Seed meter setup and adjustment, Meter rain cover, Seed inlet shutter adjustment – Great Plains 2525A Operator Manual User Manual

Page 50: Meter rain cover seed inlet shutter adjustment, 05 | ii iii

Advertising
background image

46

2025A/2525A

Table of Contents

Index

Great Plains Manufacturing, Inc.

118-999M

Table of Contents

Index

2013-06-04

Seed Meter Setup and Adjustment

There are adjustments for seed inlet, and choice of disks.
There are no other adjustments, and in particular no
brush adjustments, at the meter.

Meter Rain Cover
The rain cover keeps side winds from unseating seed in
disk pockets. It also keeps precipitation, sunlight and
field debris out of the meters.

Refer to Figure 43

To remove the rain cover, peel the flexible snap latches,
at top

and rear

, away from the meter housing. Pivot

the cover forward and down at tab

in slot.

When removing a cover, inspect it for damage and miss-
ing parts. If a cover does not have both latches, and an
intact edge seal under the latches, the cover is apt to be
lost during transport or field operations.

To replace a latch, temporarily remove the seal near the
latch. Slide the replacement latch onto the cover lugs
from the meter side, then snap the other end down over
the lugs. Re-install the seal.

Seed Inlet Shutter Adjustment

Refer to Figure 44 (showing the shutter at setting 3)

The seed inlet shutter regulates the volume of bulk seed
presented to the seed disk. The operating settings vary
with crop, seed size and treatments. The shutter also has
settings for row shut-off (completely closed), and
clean-out (wide open).

The Seed Rate Charts include suggested initial shutter
settings. Refine these settings based on experience, and
on inspection of the slope of the seed pool at the bottom
of the seed disk.

The shutter is operated by a handle. Lift the handle away
from the meter plate. Move the handle to half a setting
higher than the new setting, then back to the new setting,
and lower the pawl into that slot.

The table at right is a general summary of shutter set-
tings.

Figure 43

Rain Cover Removal

29606

1

2

3

1

2

3

Figure 44

Seed Inlet Shutter

29607

0

5

|

II

III

||||

Setting

Setting Typically Used For

Top (0)

Closed: Row Shut-Off, Meter Re-Fill

| (1)

Small seeds, such as Milo, with little or

no treatments

|| (2)

Small treated seeds and edible beans

(such as Soybeans)

||| (3)

Corn, round popcorn

|||| (4)

Large corn, or heavily treated corn

Bottom (5)

Wide Open: Clean-Out

Advertising
This manual is related to the following products: