Seed Pool Troubleshooting

29832

Figure 63

Rear Cross-Section of Air-Pro

®

Meter in Normal and Row-Failed Conditions

29832

Normal: Filled

Delivery Blockage

Bridging: Inlet Screen

Bridging: Inlet Shutter

Inlet is filled to seed box.
Seed move slowly down as
singulated by meter.

No seed arriving from box.
Air back-flow

is occurring.

Causes may include:

• seed run-out

• blockage in seed box

• plugged sliding seed tube

• seed tube plug installed in

seed box

• foreign matter in seed

• excessive or sticky seed

treatment

Oversize matter in seed has
caused a bridge at the top of
the inlet.

Air back-flow

is occurring,

which can reduce meter
pressure at other rows.

A bridge at the shutter is
blocking flow. Causes may
include:

• oversize seed

• shutter setting too low

• oversize matter in seed

Actions:

Actions:

Actions:

Actions:

No action required.

Continue Planting.

1.

Correct cause of block-
age.

2.

Resume planting.

1.

Close shutter.

2.

Tap on screen cone and
inspect.

3.

Remove lock ring. Lift
sliding seed tube off
inlet if step 2 doesn’t
clear,

4.

Check seed pool for for-
eign matter.

5.

Resume planting.

1.

If shutter was at sug-
gested opening,
increase one notch.

2.

Check seed pool for for-
eign matter.

3.

Resume planting.

1

1

1