Clutch operation, Clutch overrides – Great Plains YP3025A Operator Manual User Manual

Page 51

Advertising
background image

Great Plains Manufacturing, Inc.

Table of Contents

Index

Operating Instructions

47

02/16/2012

Table of Contents

Index

401-705M

Clutch Operation

The YP3025A Planter has drive system clutches, which
enable or disable row unit meter drive:

• (standard) an electric clutch for each planter section

(left wing, center, tight wing; 3 clutches total), or

• (Swath Command option) a pneumatic clutch for each

row, or, on twin row, for each row pair.

Switches on the CFM provide control of clutches for the
entire planter, or for each planter section. This control is
in addition to that provided by the lift switch (all rows on/
off), and the Swath Command option (arbitrary sets of
clutches on/off).

The switches Left

/ Center

/ Right

correspond to

the left wing row units, center section row units and right
wing row units respectively.

The Master

switch controls all row units, regardless of

drive type. For all switches, “OFF” (down) removes power
from the clutch, disengaging that set of row units. When
any switch (plus Master) is ON, the LED for that switch
illuminates steadily.

The information in the table at right is normally preset at
the factory for your planter configuration.

Clutch Overrides

In the event of clutch problems, the systems are
designed to act as follows:

• Electric (section) clutches disengage on loss of power.

• Pneumatic (row) clutches engage on loss of air pres-

sure.

To continue planting until a problem can be corrected,
take these steps:

• Electric clutch (standard):

Lock-up bolts are provided to engage them in the
event of power loss or clutch slippage. See page 48 for
lock-up instructions.

• Pneumatic clutch (Swath Command™):

Other than troubleshooting, no action is required at the
clutch. Pinch off any leaking tubing to prevent pres-
sure loss at other rows.

Null4:

Figure 49

CFM: Clutch Switches

26120

1

2

3

4

Rows

Clutch Switch Coverage

Model

Left

Center

Right

YP3025A-1230

01 - 04

05 - 08

09 - 12

YP3025A-16TR36

01 - 04

05 - 12

13 - 16

YP3025A-1820

01 - 06

07 - 12

13 - 18

YP3025A-2315

01 - 07

08 - 16

17 - 23

YP3025A-2415

01 - 07

08 - 16

17 - 24

YP3025A-24TR

01 - 08

09 - 16

17 - 24

YP3025A-3610

01 - 11

12 - 25

26 - 36

YP3025A-1270

01 - 04

05 - 08

09 - 12

YP3025A-2335

01 - 08

09 - 16

17 - 23

YP3025A-24TR70

01 - 06

07 - 16

17 - 24

Row groupings controlled by CFM switches may vary from this table if
Swath Command™ is installed. Swath Command™ is not available for
row spacings below 15in (38cm).

2

3

4

1

Advertising