Liquid fertilizer adjustments – Great Plains YP3025A Operator Manual User Manual

Page 68

Advertising
background image

64

YP3025A

Table of Contents

Index

Great Plains Manufacturing, Inc.

401-705M

Table of Contents

Index

02/16/2012

Liquid Fertilizer Adjustments

Liquid fertilizer distribution systems

a

are optional on the

YP3025A Planter.

If installed, there are several points of fertilizer setup and/
or adjustment:

1.

Pump setting dial or sprockets
Basic pumping rate is adjusted at pumps.

For a cart-mounted pump, see the cart’s operation
manual.

Refer to the Seed Rate manual and the tank cart
Operator’s manual.

2.

Row orifice setup
Orifice plate sizes are chosen to assure consistent
pressure at all nozzles. Refer to the Seed Rate man-
ual.

3.

Relief valve setting
Refer to the Seed Rate manual.

4.

Inlets
Both Type 2 (2-section, single inlet) and Type 3 (3-
section, 3-inlet) systems have quick-connect inlets
and shutoff valves at the back of the planter. See
page 20 for hook-up details.

5.

Strainer setup
The optional ground drive pump includes a strainer.
The mesh screen size must be compatible with the
orifice plates in the distribution system. Refer to the
Seed Rate manual.

Great Plains recommends checking with your local
agronomist as soil conditions vary. Soil conditions in your
area may need less or more fertilizer than represented in
these charts. In furrow, do not exceed 12 gallons per
acre in any case.

The liquid fertilizer system is designed to operate (ide-
ally) between 15 and 40 psi, but in no case more than 65
psi. Several system elements affect system pressure,
and need initial setup, periodic maintenance, and adjust-
ment when changing fertilizer rates.

a. Type 2, Type 3, or both, with or without planter-mounted ground drive pumps for Type 2. See page 20 for details.

Agricultural Chemical Hazards:
Avoid contact with skin or eyes. Wear proper protective equip-
ment as required by chemical manufacturer. Avoid prolonged
breathing of chemical fumes. Wear respirator as required by
chemical manufacturer.Some chemicals will cause serious
burns, lung damage, and death. Seek medical assistance imme-
diately if accident occurs. Know what to do in case of acci-
dent.

Advertising