Using structure palettes, Using the cursor on the structurescan panel – B&G Zeus 12 User Manual

Page 52

Advertising
background image

51

Using Structure Palettes

Several display structure templates with varying degrees of

color and brightness are available.

Using the Cursor on the StructureScan

Panel

When you press one of the arrow keys the cursor will be

visible, the depth at the cursor position will be shown, the

information window and the history bar will be activated.

You use the arrow keys to move the cursor in any direction

on the display.

To remove the cursor and cursor elements from the panel, press the
‘X’

key.

Using the cursor to position a waypoint

You can position a waypoint at the cursor position by pressing the
PLOT

key as described in the Waypoints, routes and tracks

section.

When the key is pressed the waypoint symbol and ID are

positioned at the cursor position.

Viewing StructureScan history

Whenever the cursor is shown on a StructureScan panel, the

green scroll bar is also shown. The scroll bar shows the image you

are currently viewing in relation to the total StructureScan image

history stored.

Depending of the view selected either DownScan or SideScan modes— when the scroll

bar is on the far right side (DownScan) or at the bottom of the screen (SideScan)— all

indicates that you are viewing the latest soundings.

Therefore, if you move the cursor to the left side of the screen (DownScan mode) the

history bar will start scrolling towards left, and the automatic scrolling as new soundings

are received will be turned off. Conversely, if you move the cursor upwards (in SideScan

mode) the history bar will start scrolling upwards, and the automatic scrolling as new

soundings are received will be turned off.

To resume StructureScan scrolling, move the cursor until the green history bar reaches

either the right side of the image (DownScan) or bottom of the image (SidenScan), or

press the ‘X’ key.

Measuring distance

The cursor can be used to measure the distance between the position of two

observations on the StructureScan image. It is easier to use the measure function when

the sounder image is paused.

Use the following process to measure a distance:

Move the cursor to the fi rst measuring point

1

Start the Measure function

2

Move the cursor towards the second measuring

3

point

A line will be drawn from the first point to the

-

cursor, and the distance will be listed in the

Information window

You can reset the measurement by pressing the Tick key.

When you press the ‘X’ key the echosounder will resume

to normal scrolling.

MENU

WIN

MENU

WIN

x2

Advertising
This manual is related to the following products: